Series 5600 Outside Glazed Installation Instructions

Section VI: Glazing Preparation

Step #5 Install Glazing Gaskets In Mullions

A.)

Remove glazing gaskets from the reel and allow to relax and shrink.

B.)

Apply sealant into raceway a minimum of 2” in each direction from the corner.
(Refer to illustration below.)

C.)

Once the gaskets have relaxed, cut and install into position. Vertical gaskets must

be cut vertical D.L.O. plus 1 ¾”. Place into position starting at the center of the
D.L.O. Crowd the excess at the ends. [DO NOT STRETCH]

D.)

Cut the horizontal gasket D.L.O. plus ½” and insert the gasket as indicated above.

E.)

Seal all gasket corners and butt joints as indicated below.

Step #6 Installing Setting Blocks

A.)

Position and install setting blocks as directed on the approved Final drawings.

[Usually located at quarter points of D.L.O. unless noted otherwise.]

B.)

Refer to additional note for setting block requirements on page 20.

Seal the gasket race and

back side of gasket 2” in

each direction at all

corners with sealant.

To insure a snug fit, seal all gasket

corners by pulling the horizontal

gasket back, sealing the ends, and

pressing into the vertical gasket.

Seal across face of mullion

joint plug before installing

pressure plate.

Joint Plugs

Preset Gaskets