U S I N G T H E A I R F U E L R A T I O M O D U L E
Air Pump Maintenance and Troubleshooting
Version 6
Air Fuel Ratio Module Installation and User Guide
2-17
R
EPLACING
THE
F
USE
The air pump has a 3 amp 250 volt 5mm fuse located in a drawer just above the power
cord plug in. The fuse drawer contains the fuse and a spare fuse. Once you use the
spare fuse, remember to replace it with a new one.
1
Disconnect the power cable from the Air Pump Assembly. The fuse drawer will not
come out until the power cable is removed.
2
Using a flat screwdriver, gently pry the fuse drawer from the pump assembly.
Figure 2-18: Removing the Fuse Drawer
3
Remove the blown fuse.
4
Replace the blown fuse with the spare fuse located in the housing behind the fuse
holder.
Note: Be sure to replace the spare fuse with a new 3 amp 250 volt 5mm fuse
(Dynojet P/N 54210300 or equivalent).
For continued protection against risk of fire, replace only with fuse of the
specified type and current ratings.
Figure 2-19: Replacing the Fuse
fuse drawer
pry with
screwdriver
blown fuse
spare fuse
spare fuse
housing
fuse holder