The air pump has a 3 amp 250 volt 5mm fuse located in a drawer just above the power
cord plug in. The fuse drawer contains the fuse and a spare fuse. Once you use the
spare fuse, remember to replace it with a new one.
1

Disconnect the power cable from the Air Pump Assembly. The fuse drawer will not
come out until the power cable is removed.

2

Using a flat screwdriver, gently pry the fuse drawer from the pump assembly.

Figure 2-18: Removing the Fuse Drawer

3

Remove the blown fuse.

4

Replace the blown fuse with the spare fuse located in the housing behind the fuse
holder.
Note: Be sure to replace the spare fuse with a new 3 amp 250 volt 5mm fuse
(Dynojet P/N 54210300 or equivalent).

For continued protection against risk of fire, replace only with fuse of the
specified type and current ratings.

Figure 2-19: Replacing the Fuse

fuse drawer

pry with

screwdriver

blown fuse

spare fuse

spare fuse

housing

fuse holder