beautypg.com

Air pump assembly, Power requirements, Setting up the air pump assembly – Dynojet Air Fuel Ratio Module User Manual

Page 10

background image

Air Fuel Ratio Module Installation and User Guide

C H A P T E R 1
Air Pump Assembly

1-6

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

AIR PUMP ASSEMBLY

This section describes how to set up the Air Pump Assembly. Dynojet recommends
running the pump between dyno runs to help reduce the chance of moisture
contamination on the sensor. Always keep the pump in the upright position.
Refer to “Air Pump Maintenance and Troubleshooting” on page 2-7 for more
information.

P

OWER

R

EQUIREMENTS

The Air Pump Assembly is supplied with either a 120 volt standard power plug or 240
volt European power plug. The current draw for both is less than 2.0 amps. Both
power plugs use a 3 amp 250 volt 5x20 mm fuse.

S

TANDARD

E

UROPEAN

P

OWER

P

LUG

The Interpower™ Schuko power cord is suitable for use in Germany, Austria, Norway,
Sweden, Finland, the Netherlands, Belgium, France, Portugal, and Spain. You must
install the appropriate power plug specifically for your country to ensure proper
grounding.

S

ETTING

U

P

THE

A

IR

P

UMP

A

SSEMBLY

The Air Pump Assembly comes pre-assembled and ready to use.
1

Attach the power cord to an outlet.

2

Secure the sensor to the pump assembly.

3

Turn on the main power switch.

Figure 1-4: Air Pump Assembly

sensor

power switch

power cord plug

filter assembly