C H A P T E R 2
Air Pump Maintenance and Troubleshooting
2-8
I
F
W
ATER
IS
C
OLLECTING
IN
THE
F
ILTER
B
OWL
Do not allow the filter bowl to fill with water during operation. Use the following
instructions to troubleshoot excess water in the filter bowl.
1
Unscrew the filter bowl from the filter housing and verify there is no blockage in
the filter bowl.
2
Verify the fitting at the bottom of the bowl is not clogged. Clean if necessary.
3
Turn the pump on and check for air flow through the small hose. If you do not
have air flow through this hose, continue with the next step.
Figure 2-7: Check Filter Bowl and Air Flow
4
Remove the pump head service cover.
Figure 2-8: Remove the Pump Head Service Cover
filter bowl
fitting
small hose
pump head
service cover