Drill and drill bit requirements, Electrical requirements, Environmental requirements – Dynojet 424xlc2: Pre-Installation Guide User Manual
Page 13: Fire suppression
![background image](/manuals/635790/13/background.png)
D Y N O P R E - I N S T A L L A T I O N I N F O R M A T I O N
Specifications and Requirements
Version 5
Pre-Installation Guide for Model 224 and 424 Automotive Dynamometers
5
D
RILL
AND
D
RILL
B
IT
R
EQUIREMENTS
You will need to provide a drill and drill bit capable of drilling holes in concrete. Refer
to Appendix A for more information on installing Red Head Anchors.
• drill bit size: 1/2-inch
• minimum hole depth: 1 5/8-inch (41.2 mm)
E
LECTRICAL
R
EQUIREMENTS
Each optional eddy current brake requires a power socket that you may order ahead
of time and install.
• Domestic: P/N 43826430 Receptacle, Turnlock, 30A, 125/250
• European: P/N 43826431 Power Socket, AC, IEC, 30A, 250V
E
NVIRONMENTAL
R
EQUIREMENTS
F
IRE
S
UPPRESSION
Always have adequate fire suppression or fire extinguishers in your dyno room.
description
specifications
Power Requirements: 4WD electronics
110v 60Hz or 240v 50Hz
Power Requirements: dyno electronics
110v 60Hz or 240v 50Hz
Power Requirements: AFR-3 air pump
110v 60Hz or 240v 50Hz
Power Requirements: hydraulic motor
110v 60Hz or 240v 50Hz or 60Hz
Power Requirements: computer
110v 60Hz or 240v 50Hz
Power Requirements: optional eddy
current brake
240v 30amp single-phase circuit for each eddy current
brake
Refer to Appendix B for power requirements and
installation.
description
specifications
Temperature
operating min./max
10°C/50°C (50°F/122°F)
storage min./max
0°C/70°C (32°F/158°F)
Humidity
0 to 95% non-condensing