DSS Networks 8261-RTM User Manual
Page 45

Gigabit Ethernet Metro-Switch
Board and Firmware Users Manual
DSS NETWORKS, INC.
Version: 1.14g
Page: 45
metro-sw> girule set 0 0 0 0 0 0 0xa0
# set action bits 5 and 7 (send to
port)
midx: 00, eidx: 00
# (and increment counter)
metro-sw> girule set 0 0 2 0 0 0 0x21
# dest-port=1, untag-bit, ctr=0
midx: 00, eidx: 02
metro-sw> girule set 0 0 5 0x08 0 0x45 0
# set FILTER-2 (for dataoff-2 filter)
midx: 00, eidx: 05
metro-sw> eereg set 3 5 0 0 0 0x5 0 0xff
# enable mirroring on port 0 egress
port 1
metro-sw> cfg save
# save configuration to eeprom