beautypg.com

Pin no. signal dte direction description – Salter Brecknell 1200 Series User Manual

Page 22

background image

Model 122X MiniPrinter User’s Manual

22

Serial Interface Voltage Levels

Received data:
Mark = OFF = Logic “1” = -25V to -3V
Space = ON = Logic “0” = +25V to +3V

Clear to send:
Busy = OFF = Logic “1” = -9V
Not Busy = ON = Logic “0” = +9V

Transmitted data:
Mark = OFF = Logic “1” = -9V
Space = ON = Logic “0” = +9V

Model 1220 (2600)

RS-232 Serial Version

Pin No. Signal

DTE Direction Description

1

Chassis ground

_

Cable shield

2

(RD) Received data

To printer

Printer data input line

5

(CTS) Clear to send

From printer

Signal (equivalent to

BUSY) indicating that

printer is ready for

operation and can

receive data.

7

(SG) Signal

_

Signal Ground

The

rest

are not