beautypg.com

Salter Brecknell 1200 Series User Manual

Page 18

background image

Model 122X MiniPrinter User’s Manual

18

T/D Format

This feature is avail-
able only on units with
the time/date option
installed.

Time/date option is
Y2K compatible.

Auto Seq#

Auto T&D

Pound Sign

Zero

_Underscore

Busy Invert

Appears only if the
clock is installed.

TIME/DATE FORMAT is the next parameter. Choose
from the following formats.

MM/DD/YY hh:mm ?M
MM/DD/YY hh:mm ?M DOW

MM = month

MM/DD/YY hh:mm

DD = day

MM/DD/YY hh:mm DOW

YY = year

DD-MM-YY hh:mm ?M

hh = hour

DD-MM-YY hh:mm ?M DOW

mm = minutes

DD-MM-YY hh:mm

?M = AM or PM

DD-MM-YY hh:mm DOW

DOW=Day of week

DD-MON-YY hh:mm ?M
DD-MON-YY hh:mm ?M DOW
DD-MON-YY hh:mm
DD-MON-YY hh:mm DOW
NONE

AUTO TIME AND DATE is the next parameter.
Your choices are:

YES -

autoprint after CR (carriage return)

NO -

do not autoprint after CR

Autoprint of the time and date will not occur unless
three seconds has elapsed since the printer has
stopped printing.

AUTO SEQUENCE NUMBER is the next parameter.
Choices:

YES - autoprint sequence number after CR
NO -

don’t autoprint sequence number after CR

Autoprint of the sequence number will not occur
unless three seconds has elapsed since the printer
has stopped printing.

ZERO is the next parameter. Choose how you want
the zero character to look in your printouts. Choose
between 0 and Ø.

POUND SIGN is the next parameter. Choose to show
pound as # or as the British sterling pound symbol £.

_UNDERSCORE is the next parameter. Choose
which symbol the same ASCII code will print, an
underscore (_) or a left arrow (Ô).

BUSY INVERT is next. This controls the logic level for
a busy signal for the CTS line.
Choices:

YES -

voltage will be in a low state until the
unit is busy then voltage level goes high.

NO -

voltage will be in a high state until the
unit is busy then voltage level goes low.