beautypg.com

2 communication, 1 rs-232 serial interface, 2 cp103 printer ps/2 connector – Salter Brecknell CP103 User Manual

Page 8: Chapter 2 communication

background image

6

CP103 Thermal Printer User Instructions

2 Communication

The CP103 Mini Thermal Printer uses a RS-232 serial interface connection with the
host communication. If a serial port is unavailable on the host device, it is possible to
use a serial / USB converter.

2.1 RS-232 Serial Interface

RS-232 is developed according to the EIA standard asynchronous transmission serial
interface. The specifications are as following:

l

Data transmission: serial interface

l

Synchronization: asynchronous

l

Signal Level: RS-232 level, logic 1:-5.4v, logic 0: +5.4v

l

Hardware Flow Control: optional

l

Baud rate: 1200 bps to 115200 bps (NOTE: At 1200 baud, continous
printing mode of data sending from Host is not supported)

l

Data word length: 8 bits

l

Stop bit: 1bit

l

Parity: None

The printer self-testing page will show the current baud rate. The default baud rate is
115200bps. Refer to Chapter

3

for details on the Printer Self Test.

2.2 CP103 Printer PS/2 Connector

The following drawing illustrates the PS2 socket pinout located on the CP103 printer.
This connection is used for RS-232 communication with an indicator or computer and
requires the PS2 to RS-232 interface cable (serial cable).

Pin

Description

1

TXD - data output

2

no connection

3

GND

4

no connection (12V DC- IN is optional)

5

RXD - data input

6

no connection (12V DC- IN is optional)