beautypg.com

Dataproducts parallel interface, Dataproducts parallel interface signals, Chapter 5 – Compaq P5000 Series User Manual

Page 120

background image

120

Chapter

5

Dataproducts Parallel Interface

Dataproducts Parallel Interface

The Dataproducts parallel interface allows the printer to operate with a 50-pin
Amplimite (AMP) HDH-20 data cable connector. The length of the data cable
from the host computer to the printer must not exceed 40 feet (12 meters).

Dataproducts Parallel Interface Signals

Dataproducts-compatible interface signals between the host computer and
the printer are defined as follows:

Data Lines 1 through 8. Provide eight standard or inverted levels from the
host that specify character data, plot data, or a control code. Data Line 8
allows access to the extended ASCII character set. You can enable or disable
this line via the Data Bit 8 parameter on the Dataproducts submenu (page
109)
.

Data Strobe. Carries a high true pulse from the host when data is ready. The
data strobe remains high until the Data Request line goes false. The active

Table 11. Dataproducts Parallel Interface Connector Pin Assignments

(with a 50-pin AMP HDH-20 Data Cable Connector)

Input Signals

Output Signals

Miscellaneous

Signal

Pin

Signal

Pin

Signal

Pin

DATA LINE 1

Return

19
3

READY

Return

22
6

CABLE VERIFY

45, 46

DATA LINE 2

Return

20
4

ONLINE

Return

21
5

GROUND

39

DATA LINE 3

Return

1
2

DEMAND/DATA REQ.

Return

23
7

TEST

12

DATA LINE 4

Return

41
40

PARITY ERROR

Return

27
11

DATA LINE 5

Return

34
18

DATA LINE 6

Return

43
42

DATA LINE 7

Return

36
35

DATA LINE 8

Return

28
44

DATA STROBE

Return

38
37

PAPER INSTRUCTION

Return

30
14

BUFFER CLEAR

Return

31
15

NOTE: Pins not listed are not connected.