In use, the CGA Tailpiece couples to the fill connection on the container being filled. The

Relief Valve vents pressure over 350 psig (24 bar/2413 kPa) that builds up in the fill line

due to trapped liquid. The Dump Valve is used to allow the operator to blow-don the

receiving container during a pump fill, or to relieve residual pressure from expanding liquid

trapped in the line before disconnecting the fill line.

Fill kits are available with different combinations of hose length and fittings for a specific

gas service. The following chart identifies the available transfer hoses and fill tee assem-

blies.

TRANSFER HOSE CHART

Description

Cylinder

End

Part

(Service/Hose Length) Connections(s)

Fittings

Number

Inert (N2,Ar) Service

4 ft. (1.2 m) Stainless Steel

LIQUID or VENT Valve CGA 295 to 3/8 in. NPT

1700-9C65

6 ft. (1.8 m) Stainless Steel

LIQUID or VENT Valve CGA 295 to 3/8 in. NPT

1600-9C66

6 ft. (1.8 m) Stainless Steel

USE Valve

CGA 580 to 3/8 in. NPT

GL50-8C51

Oxygen Service

6 ft. (1.8 m) Stainless Steel

LIQUID or VENT Valve CGA 440 to 3/8 in. NPT

GL50-8C53

6 ft. (1.8 m) Stainless Steel

USE Valve

CGA 540 to 3/8 in. NPT

GL50-8C56

Carbon Dioxide Service

6 ft. (1.8 m) Stainless Steel

LIQUID or USE Valve

CGA 320 to 3/8 in. NPT

HP50-8C51

4 ft. (1.2 m) Stainless Steel

VENT Valve

CGA 295 to 3/8 in. NPT

1700-9C65

6 ft. (1.8 m) Stainless Steel

VENT Valve

CGA 295 to 3/8 in. NPT

1600-9C66

Nitrous Oxide Service

4 ft. (1.2 m) Stainless Steel

VENT Valve

CGA 295 to 3/8 in. NPT

1700-9C65

6 ft. (1.8 m) Stainless Steel

VENT Valve

CGA 295 to 3/8 in. NPT

1600-9C66

Fill Hose Kits

11