ASSEMBLY INSTRUCTIONS
The DH is shipped fully assembled. The handle is assembled in
the lower position (dotted line Fig. 1). To position handle in the
upright position, remove bolts securing the handle to the support
legs, lift handle until the handle holes line up with the upper holes
in the support legs and insert bolts to secure the handle in the full
upright position.
WIRING INSTRUCTIONS
1. Use heater only on the voltage and frequency specified on
the nameplate.
2. All wiring should be done in accordance with local codes and
the National Electrical Code by a qualified person.
3. Branch circuit wire for connection to heater must be at least
90°C wire.
4. The top access panel is secured by 4 screws that must be
loosened to gain access.
5. A ground terminal is provided near the power terminal board.
The ground wire should be connected before other
connections are made.
6. Refer to Chart A for proper size “SO” grade cable.
7. A proper strain relief must be used with “SO” grade cable.
8. Dragon heaters are factory pre-wired for 3-phase delta
operation. Some units can be converted to single phase
operation by changing the wiring. Refer to Chart A for those
heaters that can be converted to single phase. The
appropriate wiring diagram is also located on the back of the
wiring compartment cover.
Risk of fire. Do not use as a residential or household heater.
a
WARNING
!
Hazard of Fire or Discoloration of Temperature Sensitive
Fabrics. Do not use as a residential or household heater. Keep
combustible material and such fabrics away from heater. Do
not operate heater where flammable vapors, gases or liquids
are present. Heaters in the heat mode should not be operated
in room temperatures above 80°F. Fan motor is not designed
to operate in ambients below -40°F.
To avoid personal injury read “IMPORTANT INSTRUCTIONS”
before installation or operation of heater.
a
WARNING
!
Keep electrical cords and combustible materials, such as
drapes and other furnishings, away from heater.
a
WARNING
!
Bolt ( )
Nut ( )
Support Leg
Handle
Direction of
Airflow
Figure 1
ELECTRIC SHOCK HAZARD. Disconnect all power before
installing or servicing heater. Failure to do so could result in
personal injury or property damage. Heater must be effectively
grounded in accordance with the National Electrical Code,
NFPA 70.v
a
WARNING
!
2
Fits Cable Dia.
Plug Type
Model
Description
Volts Amps Configuration NEMA # ANSI #
.385”-.780”
Locking
LPS25124 3 Pole, 4 Wire
250
20
L15-20 C73.85
.385”-.780”
Locking
LPS25103 3 Pole, 4 Wire
250
30
L15-30 C73.86
.595”-1.150”
Locking
LPS25104 3 Pole, 4 Wire
480
30
L16-30 C73.88
.595”-1.150”
Locking
LPS25084 3 Pole, 4 Wire
600
30
L17-30 C73.89
.750”-1.125”
Locking
LPS25083 2 Pole, 4 Wire
600
50
—
—
.750”-1.125”
Locking
LPS25064 3 Pole, 4 Wire
600
50
—
—
.625”-1.187”
Non Locking NPS25650 2 Pole, 3 Wire
250
50
6-50
C73.53
.390”-.775”
Non Locking
NPS1520
3 Pole, 4 Wire
250
20
15-20
C73.59
.750”-1.250”
Non Locking
NPS1550
3 Pole, 4 Wire
250
50
15-50
C73.61
Plug Specifications
G
G
W
X
Z
G
W
X
Z
X
G
Y
Z
X
G
Y
Z
X
G
Y
Z
X
G
Y
Z
Y
X
G
Y
X
Z
WIRING
25 FT
OPTIONAL PLUGS
MODEL
DIAGRAM
SHIP
WIRE
CORD
LOCKING
NON-LOCK
NUMBER
KW
VOLTS
BTUH
PH
AMPS
NUMBER
WT.
SIZE
SET
TYPE
TYPE
DH1021C*
10
240
34,120
1
41.7
N/A
65 lbs
N/A
Included*
-
Included
DH0783
7.5
208
25,590
1
36.3
1A
65 lbs
8/3
CS25083
-
NPS25650
3
21
1
10/4
CS25104
LPS25103
NPS1550
DH1023
10
240
34,120
1
40.8
1A
65 lbs
6/3
CS25063
-
NPS25650
3
23.6
1
10/4
CS25104
-
NPS1550
DH1583
15
208
51,180
3
41.8
1
65 lbs
6/4
CS25064
-
NPS1550
DH1523
15
240
51,180
3
36.3
1
65 lbs
8/4
CS25084
-
NPS1550
DH1521
15
240
51,180
1
62.5
1A
65 lbs
4/4
CS25044
-
NPS1550
DH1543
15
480
51,180
1
31.4/18.2
2A
65 lbs
8/3
CS25083
LPS25083
-
3
2
12/4
CS25124
LPS25104
-
DH2043
20
480
68,240
1
41.6/24.4
4A
75 lbs
6/3
CS25063
LPS25083
-
3
4
10/4
CS25104
LPS25084
-
DH3043
30
480
102,360
3
36.3
4
75 lbs
6/4
CS25064
LPS25064
DH3063
30
600
102,360
3
29.1
4
75 lbs
8/4
CS25084
LPS25084
*Model DH1021C is shipped with 10 ft. power cord and plug.
Note: All units are factory wired for 3 phase operation. Models designated 1 and 3 phase can be field wired for single phase operation.
Chart A