Tap controller block diagram, Tap electrical characteristics – Cypress CY7C1165V18 User Manual
Page 16
CY7C1161V18, CY7C1176V18
CY7C1163V18, CY7C1165V18
Document Number: 001-06582 Rev. *D
Page 16 of 29
TAP Controller Block Diagram
Figure 3. Tap Controller Block Diagram
TAP Electrical Characteristics
The Tap Electrical Characteristics table over the operating range follows.
Parameter
Description
Test Conditions
Min
Max
Unit
V
OH1
Output HIGH Voltage
I
OH
=
−2.0 mA
1.4
V
V
OH2
Output HIGH Voltage
I
OH
=
−100 μA
1.6
V
V
OL1
Output LOW Voltage
I
OL
= 2.0 mA
0.4
V
V
OL2
Output LOW Voltage
I
OL
= 100
μA
0.2
V
V
IH
Input HIGH Voltage
0.65 V
DD
V
DD
+ 0.3
V
V
IL
Input LOW Voltage
–0.3
0.35 V
DD
V
I
X
Input and Output Load Current
GND
≤ V
I
≤ V
DD
–5
5
μA
0
0
1
2
.
.
29
30
31
Boundary Scan Register
Identification Register
0
1
2
.
.
.
.
106
0
1
2
Instruction Register
Bypass Register
Selection
Circuitry
Selection
Circuitry
TAP Controller
TDI
TDO
TCK
TMS
Notes
13. These characteristic pertain to the TAP inputs (TMS, TCK, TDI and TDO). Parallel load levels are specified in the Electrical Characteristics table.
14. Overshoot: V
IH
(AC) < V
DDQ
+ 0.35V (pulse width less than t
CYC
/2), Undershoot: V
IL
(AC) >
−
0.3V (pulse width less than t
CYC
/2)