Tools to Help Solve Problems: Dell Precision Workstation 470 and 670 Computers User's Guide
file:///T|/htdocs/systems/ws670/EN/ug_en/advtrbl.htm[3/20/2013 9:31:57 AM]
Ensure that nothing is blocking the airflow vents and that all the fans are properly installed and operating
correctly. Also, ensure that the processor heat sink is properly installed.
Alert! Previous Voltage Failure —
See "
Alert! System Battery Voltage is Low —
Replace the battery.
Alert! Uncorrectable Memory Error Previously Detected... Address xxxxxxxxh, Device DIMM_Y —
See "
Attachment failed to respond —
See "
Bad command or file name —
Ensure that you spelled the command correctly, put spaces in the proper
place, and used the correct path name.
Bad error-correction code (ECC) on disk read —
See "
bb/dd/f: Error allocating IRQ for PCI Device —
bb/dd/f: Error allocating I/O Bar for PCI Device —
bb/dd/f: Error allocating Mem BAR for PCI Device —
bb/dd/f: Error allocating PMem BAR for PCI Device —
bb/dd/f: Error allocating Upper Memory Block for PCI Device —
where bb is the bus number,dd is the device number, and f is the function number. All numbers are
in hexadecimal —
The computer encountered a problem while trying to configure an expansion card or integrated LegacySelect
device.
If the device number points to an expansion card, the card can be removed. If the device number points to an
integrated device, disable the device in
Controller has failed —
See "
Data error —
See "
Decreasing available memory —
See "
Diskette drive 0 seek failure —
See "
."
Diskette read failure —
See "
."
Diskette subsystem reset failed —
Run the
.
Diskette write protected —
Slide the write-protect notch to the open position.
Drive not ready —
Put a floppy disk in the drive.