Dell PowerEdge C6100 User Manual
Page 23

23
Using the Baseboard Management Controller
Table 1-21. PEF and Alerting Commands (NETFUN: 04H, 05H)
Commands
NetFn
CMD
O/M
Supported
Get PEF Capabilities
S/E
10H
O
Yes
Arm PEF Postpone Timer
S/E
11H
O
Yes
Set PEF Configuration Parameters
S/E
12H
O
Yes
Get PEF Configuration Parameters
S/E
13H
O
Yes
Set Last Processed Event ID
S/E
14H
O
Yes
Get Last Processed Event ID
S/E
15H
O
Yes
Alert Immediate
S/E
16H
O
Yes
PET Acknowledge
S/E
17H
O
Yes
Table 1-22. SEL Commands (NETFUN: 0AH, 0BH)
Commands
NetFn
CMD
O/M
Supported
Get SEL Info
Storage
40H
M
Yes
Get SEL Allocation Info
Storage
41H
O
Number of possible allocation units:
909
Unit size in bytes: 18
Max record size in allocation units: 18
Yes
Reserve SEL
Storage
42H
O
Yes
Get SEL Entry
Storage
43H
M
Yes
Add SEL Entry
Storage
44H
M
Yes
Partial Add SEL Entry
Storage
45H
N
No
Delete SEL Entry
Storage
46H
O
Yes
Clear SEL
Storage
47H
M
Yes
Get SEL Time
Storage
48H
M
Yes
Set SEL Time
Storage
49H
M
Yes
Get SEL Time UTC Offset Storage
5CH
O
Yes
Set SEL Time UTC Offset Storage
5DH
O
Yes
Get Auxiliary Log Status
Storage
5AH
N
No
Set Auxiliary Log Status
Storage
5BH
N
No