Dell POWEREDGE 1950 User Manual
Page 22

22
About Your System
E2016
Int Controller
Interrupt controller failure.
See "Getting Help" on page 125.
E2017
Timer Fail
Timer refresh failure.
See "Getting Help" on page 125.
E2018
Prog Timer
Programmable interval timer error. See "Getting Help" on page 125.
E2019
Parity Error
Parity error.
See "Getting Help" on page 125.
E201A
SIO Err
SIO failure.
See "Getting Help" on page 125.
E201B
Kybd Controller
Keyboard controller failure.
See "Getting Help" on page 125.
E201C
SMI Init
System management interrupt
(SMI) initialization failure.
See "Getting Help" on page 125.
E201D
Shutdown Test
BIOS shutdown test failure.
See "Getting Help" on page 125.
E201E
POST Mem Test
BIOS POST memory test failure.
See "Troubleshooting System
Memory" on page 102. If the
problem persists, see "Getting
Help" on page 125.
E201F
DRAC Config
Dell remote access controller
(DRAC) configuration failure.
Check for specific error messages.
Ensure that DRAC cables and
connectors are properly seated. If
the problem persists, see your
DRAC documentation.
E2020
CPU Config
CPU configuration failure.
Check for specific error messages.
E2021
Memory
Population
Incorrect memory configuration.
Memory population order
incorrect.
Check for specific error messages.
See "Troubleshooting System
Memory" on page 102.
E2022
POST Fail
General failure after video.
Check for specific error messages.
E2110
MBE Crd # DIMM ##
& ##
One of the DIMMs in the set
implicated by "## & ##" has had a
memory multi-bit error (MBE). If
no memory card is present, the
"Crd #" string is left out of the
message.
See "Troubleshooting System
Memory" on page 102.
Table 1-7.
LCD Status Messages (continued)
Code
Text
Causes
Corrective Actions