beautypg.com

Dell POWEREDGE 1950 User Manual

Page 20

background image

20

About Your System

E1624

PS Redundancy

The power supply subsystem is no
longer redundant. If the last supply
fails, the system will go down.

See "Troubleshooting Power
Supplies" on page 100
.

E1710

I/O Channel Chk

The system BIOS has reported an
I/O channel check.

See "Getting Help" on page 125.

E1711

PCI PERR B## D##

F##

PCI PERR Slot #

The system BIOS has reported a
PCI parity error on a component
that resides in PCI configuration
space at bus ##, device ##,
function ##.

The system BIOS has reported a
PCI parity error on a component
that resides in the specified PCI
slot.

Remove and reseat the PCI
expansion cards. If the problem
persists, see "Troubleshooting
Expansion Cards" on page 107.

If the problem persists, the riser
card or system board is faulty. See
"Getting Help" on page 125.

E1712

PCI SERR B## D##

F##

PCI SERR Slot #

The system BIOS has reported a
PCI system error on a component
that resides in PCI configuration
space at bus ##, device ##,
function ##.

The system BIOS has reported a
PCI system error on a component
that resides in the specified slot.

Remove and reseat the PCI
expansion cards. If the problem
persists, see "Getting Help" on
page 125.

If the problem persists, the riser
card or system board is faulty. See
"Getting Help" on page 125.

E1714

Unknown Err

The system BIOS has determined
that there has been an error in the
system, but is unable to determine
its origin.

See "Getting Help" on page 125.

E171F

PCIE Fatal Err

B## D## F##

PCIE Fatal Err

Slot #

The system BIOS has reported a
PCIe fatal error on a component
that resides in PCI configuration
space at bus ##, device ##,
function ##.

The system BIOS has reported a
PCIe fatal error on a component
that resides in the specified slot.

Remove and reseat the PCI
expansion cards. If the problem
persists, see "Troubleshooting
Expansion Cards" on page 107.

If the problem persists, the riser
card or system board is faulty. See
"Getting Help" on page 125.

E1810

HDD ## Fault

The SAS subsystem has
determined that hard drive ## has
experienced a fault.

See "Troubleshooting a Hard
Drive" on page 104.

Table 1-7.

LCD Status Messages (continued)

Code

Text

Causes

Corrective Actions