Dell POWEREDGE 1950 User Manual
Page 21

About Your System
21
E1811
HDD ## Rbld Abrt
The specified hard drive has
experienced a rebuild abort.
See "Troubleshooting a Hard
Drive" on page 104. If the problem
persists, see your RAID
documentation.
E1812
HDD ## Removed
The specified hard drive has been
removed from the system.
Information only.
E1913
CPU & Firmware
Mismatch
The BMC firmware does not
support the CPU.
Update to the latest BMC
firmware. See the BMC User’s
Guide for more information on
setup and use of BMC.
E1A14
SAS Cable A
SAS cable A is missing or bad.
Reseat the cable. If the problem
persists, replace the cable. See
"SAS Controller Daughter Card"
on page 56.
E1A15
SAS Cable B
SAS cable B is missing or bad.
Reseat the cable. If the problem
persists, replace the cable. See
"SAS Controller Daughter Card"
on page 56.
E1A17
Pwr Cable FB
Flex bay power cable is missing or
bad.
Reseat the cable. If the problem
persists, replace the cable. See
"SAS Controller Daughter Card"
on page 56.
E1A18
PDB Ctrl Cable
Flex bay control signals cable is
missing or bad.
Reseat the cable. If the problem
persists, replace the cable. See
"SAS Controller Daughter Card"
on page 56.
E2010
No Memory
No memory is installed in the
system.
Install memory. See "Installing
Memory Modules" on page 65.
E2011
Mem Config Err
Memory detected, but is not
configurable. Error detected
during memory configuration.
See "Troubleshooting System
Memory" on page 102.
E2012
Unusable Memory
Memory is configured, but not
usable. Memory subsystem failure.
See "Troubleshooting System
Memory" on page 102.
E2013
Shadow BIOS Fail
The system BIOS failed to copy its
flash image into memory.
See "Troubleshooting System
Memory" on page 102.
E2014
CMOS Fail
CMOS failure. CMOS RAM not
functioning properly.
See "Getting Help" on page 125.
E2015
DMA Controller
DMA controller failure.
See "Getting Help" on page 125.
Table 1-7.
LCD Status Messages (continued)
Code
Text
Causes
Corrective Actions