E1418
CPU # Presence
Specified processor is missing or
bad, and the system is in an
unsupported configuration.
See "Troubleshooting the
Microprocessors" on page 108.
E141C
CPU Mismatch
Processors are in a configuration
unsupported by Dell.
See "System Memory" on page 63.
Ensure that your processors match
and conform to the type described
in the Microprocessor Technical
Specifications outlined in your
system’s Getting Started Guide.
E141F
CPU Protocol
The system BIOS has reported a
processor protocol error.
See "Getting Help" on page 125.
E1420
CPU Bus PERR
The system BIOS has reported a
processor bus parity error.
See "Getting Help" on page 125.
E1421
CPU Init
The system BIOS has reported a
processor initialization error.
See "Getting Help" on page 125.
E1422
CPU Machine Chk
The system BIOS has reported a
machine check error.
See "Getting Help" on page 125.
E1610
PS # Missing
No power is available from the
specified power supply; specified
power supply is improperly
installed or faulty.
See "Troubleshooting Power
Supplies" on page 100.
E1614
PS # Status
No power is available from the
specified power supply; specified
power supply is improperly
installed or faulty.
See "Troubleshooting Power
Supplies" on page 100.
E1618
PS # Predictive
Power supply voltage is out of
acceptable range; specified power
supply is improperly installed or
faulty.
See "Troubleshooting Power
Supplies" on page 100.
E161C
PS # Input Lost
Power source for specified power
supply is unavailable, or out of
acceptable range.
Check the AC power source for the
specified power supply. If the
problem persists, see
"Troubleshooting Power Supplies"
on page 100.
E1620
PS # Input Range
Power source for specified power
supply is unavailable, or out of
acceptable range.
Check the AC power source for the
specified power supply. If the
problem persists, see
"Troubleshooting Power Supplies"
on page 100.
Table 1-7.
LCD Status Messages (continued)
Code
Text
Causes
Corrective Actions