No timer tick interrupt
Faulty server module board.
See "
Getting Help
."
Not a boot diskette
Not a bootable diskette.
Use a bootable diskette.
PCI BIOS failed to install
Faulty or improperly installed
PCIe daughter card.
Reseat the daughter card. See "
Daughter Card
" in "Installing System
Options." If the problem persists, see "
Getting Help
."
PCIe Degraded Link Width Error: Embedded
Bus#nn/Dev#nn/Funcn
Expected Link Width is n
Actual Link Width is n
Faulty or improperly installed
PCIe daughter card.
Reseat the daughter card. See "
Daughter Card
" in "Installing System
Options." If the problem persists, see "
Getting Help
."
PCIe Degraded Link Width Error: Slot n
Expected Link Width is n
Actual Link Width is n
Faulty or improperly installed
PCIe daughter card.
Reseat the daughter card. See "
Daughter Card
" in "Installing System
Options."If the problem persists, see "
Getting Help
."
PCIe Training Error: Embedded
Bus#nn/Dev#nn/Funcn
Faulty or improperly installed
PCIe daughter card.
Reseat the daughter card. See "
Daughter Card
" in "Installing System
Options." If the problem persists, see "
Getting Help
."
PCIe Training Error: Slot n
Faulty or improperly installed
PCIe daughter card.
Reseat the daughter card. See "
Daughter Card
" in "Installing System
Options." If the problem persists, see "
Getting Help
."
Plug & Play Configuration Error
Error encountered in
initializing PCI device; faulty
server module board.
Set the NVRAM_CLR switch to "on" and reboot the server module. See
Figure A
-2
for switch location. Check for a BIOS update. If the problem
persists, see "
Getting Help
."
Read fault
Requested sector not found
Faulty diskette, diskette
drive, optical drive, or hard
drive.
Replace the diskette. Ensure that the custom cable is properly connected. See
"
Troubleshooting USB Devices
" or "
Troubleshooting Hard Drives
" in
"Troubleshooting Your System" for the appropriate drive(s) installed in your
system.
Remote Configuration update attempt failed
Server module could not
implement Remote
Configuration request.
Retry Remote Configuration.
Sector not found
Seek error
Seek operation failed
Faulty diskette or hard drive. Replace the diskette. If the problem persists, see
Troubleshooting Hard
Drives
" in "Troubleshooting Your System" for the appropriate drive installed in
your system.
Shutdown failure
Shutdown test failure.
Ensure that all memory modules are properly installed. See "
Troubleshooting
Server Module Memory
" in "Troubleshooting Your System." If the problem
persists, see "
Getting Help
."
Spare bank enabled
Memory spare bank enabled. Not applicable.
The amount of system memory has changed.
Faulty memory module.
See "
Troubleshooting Server Module Memory
" in "Troubleshooting Your
System." If the problem persists, see "
Getting Help
."
Information only, if you have
changed the memory
configuration.
Time-of-day clock stopped
Faulty battery; faulty server
module board.
See "
Troubleshooting the Server Module Battery
" in "Troubleshooting Your
System." If the problem persists, see "
Getting Help
."
Time-of-day not set - please run SETUP
program
Incorrect Time or Date
settings; faulty server
module board battery.
Check the Time and Date settings See "Using the System Setup Program" in
your User's Guide. If the problem persists, see "
Troubleshooting the Server
Module Battery
" in "Troubleshooting Your System."
Timer chip counter 2 failed
Faulty server module board.
See "
Getting Help
."
Unexpected interrupt in protected mode
Faulty or improperly installed
memory modules or faulty
server module board.
Ensure that all memory modules are properly installed. See "
General Memory
Module Installation Guidelines
" in "Installing System Options." If the problem
persists, see "
Troubleshooting Server Module Memory
" in "Troubleshooting
Your System." If the problem persists, see "
Getting Help
."
Unsupported CPU combination
Mismatched processors are
installed.
Processor is not supported
by the server module.
Replace a microprocessor so that both microprocessors match. See
"
Microprocessors
" in "Installing System Options."
Check for a BIOS update using the Dell Support website at support.dell.com.
If the problem persists, install a supported processor. See "
Microprocessors
"
in "Installing System Options."
Unsupported CPU stepping detected
Processor is not supported
by the server module.
Check for a BIOS update using the Dell Support website at support.dell.com.
If the problem persists, install a supported processor. See "
Microprocessors
"
in "Installing System Options."
Warning: Detected mode change from RAID to
SCSI x of the embedded RAID subsystem.
Type of controller has
changed from optional RAID
to SCSI since previous
system boot.
Back up information on the hard drives before changing the type of controller
used with the drives.
Warning: Detected mode change from SCSI to
RAID x of the embedded RAID subsystem.
Type of controller has
changed from SCSI to
optional RAID since previous
system boot.
Back up information on the hard drives before changing the type of controller
used with the drives.
Warning! No microcode update loaded for
processor n
Unsupported processor.
Update the BIOS firmware using the Dell Support website at
support.dell.com.
Write fault
Write fault on selected drive
Faulty diskette, diskette
drive, optical drive, hard
drive.
Replace the diskette. Ensure that the custom cable is properly connected. See
"
Troubleshooting USB Devices
" or "
Troubleshooting Hard Drives
" in
"Troubleshooting Your System" for the appropriate drive(s) installed in your
system.