beautypg.com

Dell POWEREDGE 1855 User Manual

Page 27

background image

No timer tick interrupt

Faulty server module board.

See "

Getting Help

."

Not a boot diskette

Not a bootable diskette.

Use a bootable diskette.

PCI BIOS failed to install

Faulty or improperly installed
PCIe daughter card.

Reseat the daughter card. See "

Daughter Card

" in "Installing System

Options." If the problem persists, see "

Getting Help

."

PCIe Degraded Link Width Error: Embedded

Bus#nn/Dev#nn/Funcn

Expected Link Width is n

Actual Link Width is n

Faulty or improperly installed
PCIe daughter card.

Reseat the daughter card. See "

Daughter Card

" in "Installing System

Options." If the problem persists, see "

Getting Help

."

PCIe Degraded Link Width Error: Slot n

Expected Link Width is n

Actual Link Width is n

Faulty or improperly installed
PCIe daughter card.

Reseat the daughter card. See "

Daughter Card

" in "Installing System

Options."If the problem persists, see "

Getting Help

."

PCIe Training Error: Embedded

Bus#nn/Dev#nn/Funcn

Faulty or improperly installed
PCIe daughter card.

Reseat the daughter card. See "

Daughter Card

" in "Installing System

Options." If the problem persists, see "

Getting Help

."

PCIe Training Error: Slot n

Faulty or improperly installed
PCIe daughter card.

Reseat the daughter card. See "

Daughter Card

" in "Installing System

Options." If the problem persists, see "

Getting Help

."

Plug & Play Configuration Error

Error encountered in
initializing PCI device; faulty
server module board.

Set the NVRAM_CLR switch to "on" and reboot the server module. See

Figure A

-2

for switch location. Check for a BIOS update. If the problem

persists, see "

Getting Help

."

Read fault

Requested sector not found

Faulty diskette, diskette
drive, optical drive, or hard
drive.

Replace the diskette. Ensure that the custom cable is properly connected. See
"

Troubleshooting USB Devices

" or "

Troubleshooting Hard Drives

" in

"Troubleshooting Your System" for the appropriate drive(s) installed in your
system.

Remote Configuration update attempt failed

Server module could not
implement Remote
Configuration request.

Retry Remote Configuration.

Sector not found

Seek error

Seek operation failed

Faulty diskette or hard drive. Replace the diskette. If the problem persists, see

Troubleshooting Hard

Drives

" in "Troubleshooting Your System" for the appropriate drive installed in

your system.

Shutdown failure

Shutdown test failure.

Ensure that all memory modules are properly installed. See "

Troubleshooting

Server Module Memory

" in "Troubleshooting Your System." If the problem

persists, see "

Getting Help

."

Spare bank enabled

Memory spare bank enabled. Not applicable.

The amount of system memory has changed.

Faulty memory module.

See "

Troubleshooting Server Module Memory

" in "Troubleshooting Your

System." If the problem persists, see "

Getting Help

."

 

Information only, if you have
changed the memory
configuration.

 

Time-of-day clock stopped

Faulty battery; faulty server
module board.

See "

Troubleshooting the Server Module Battery

" in "Troubleshooting Your

System." If the problem persists, see "

Getting Help

."

Time-of-day not set - please run SETUP

program

Incorrect Time or Date
settings; faulty server
module board battery.

Check the Time and Date settings See "Using the System Setup Program" in
your User's Guide. If the problem persists, see "

Troubleshooting the Server

Module Battery

" in "Troubleshooting Your System."

Timer chip counter 2 failed

Faulty server module board.

See "

Getting Help

."

Unexpected interrupt in protected mode

Faulty or improperly installed
memory modules or faulty
server module board.

Ensure that all memory modules are properly installed. See "

General Memory

Module Installation Guidelines

" in "Installing System Options." If the problem

persists, see "

Troubleshooting Server Module Memory

" in "Troubleshooting

Your System." If the problem persists, see "

Getting Help

."

Unsupported CPU combination

Mismatched processors are
installed.

Processor is not supported
by the server module.

Replace a microprocessor so that both microprocessors match. See
"

Microprocessors

" in "Installing System Options."

Check for a BIOS update using the Dell Support website at support.dell.com.
If the problem persists, install a supported processor. See "

Microprocessors

"

in "Installing System Options."

Unsupported CPU stepping detected

Processor is not supported
by the server module.

Check for a BIOS update using the Dell Support website at support.dell.com.
If the problem persists, install a supported processor. See "

Microprocessors

"

in "Installing System Options."

Warning: Detected mode change from RAID to

SCSI x of the embedded RAID subsystem.

Type of controller has
changed from optional RAID
to SCSI since previous
system boot.

Back up information on the hard drives before changing the type of controller
used with the drives.

Warning: Detected mode change from SCSI to

RAID x of the embedded RAID subsystem.

Type of controller has
changed from SCSI to
optional RAID since previous
system boot.

Back up information on the hard drives before changing the type of controller
used with the drives.

Warning! No microcode update loaded for

processor n

Unsupported processor.

Update the BIOS firmware using the Dell Support website at
support.dell.com.

Write fault

Write fault on selected drive

Faulty diskette, diskette
drive, optical drive, hard
drive.

Replace the diskette. Ensure that the custom cable is properly connected. See
"

Troubleshooting USB Devices

" or "

Troubleshooting Hard Drives

" in

"Troubleshooting Your System" for the appropriate drive(s) installed in your
system.