Dell POWEREDGE 1855 User Manual
Page 26

Decreasing available memory
Faulty or improperly installed
memory modules.
Ensure that all memory modules are properly installed. See "
Troubleshooting
Server Module Memory
" in "Troubleshooting Your System."
Diskette drive 0 seek failure
Incorrect configuration
settings in System Setup
program.
Run the System Setup program to correct the settings. See "Using the System
Setup Program" in your User's Guide.
Faulty or improperly installed
diskette or optical drive to
the custom cable.
Replace the diskette. Ensure that the diskette drive and optical drive cables
are properly connected. See "
Troubleshooting USB Devices
" in
"Troubleshooting Your System."
Diskette read failure
Faulty or improperly inserted
diskette.
Replace the diskette.
Diskette subsystem reset failed
Faulty diskette drive or
optical drive controller.
Ensure that the diskette drive and optical drive cables are properly connected
to the custom cable. See "
Troubleshooting USB Devices
" in "Troubleshooting
Your System." If the problem persists, see "
Getting Help
."
Drive not ready
Diskette missing or
improperly inserted in
diskette drive.
Reinsert or replace the diskette.
Error: Incorrect memory configuration.
Ensure memory in slots DIMM1_A and
DIMM1_B, DIMM2_A and DIMM2_B, DIMM3_A and
DIMM3_B match identically in size, speed,
and rank.
One or more unmatched
pairs of memory modules are
detected.
Ensure that the memory modules are installed in matched pairs. See "
General
Memory Module Installation Guidelines
" in "Installing System Options."
Error: Incorrect memory configuration.
Memory slots DIMM3_A and DIMM3_B only
support single rank DIMMs. Remove the dual
rank DIMMs from slots DIMM3_A and DIMM3_B.
Dual-rank memory modules
are installed in slots
DIMM3_A and DIMM3_B.
Ensure that only single-rank memory modules are installed in slots DIMM3_A
and DIMM3_B. See "
General Memory Module Installation Guidelines
" in
"Installing System Options."
Error: Incorrect memory configuration.
Move DIMM3_A and DIMM3_B into DIMM2_A and
DIMM2_B.
Memory modules are not
installed in consecutive
banks.
Move memory modules from slots DIMM3_A and DIMM3_B into DIMM2_A and
DIMM2_B. See "
General Memory Module Installation Guidelines
" in "Installing
System Options."
Error: Incorrect memory configuration.
Swap the DIMMs in slots DIMM1_A and
DIMM1_B with DIMMs in slots DIMM2_A and
DIMM2_B.
If dual-rank memory
modules are installed in the
system, they must be
installed in slots DIMM1_A
and DIMM1_B.
Swap memory modules in slots DIMM2_A and DIMM2_B with modules in
DIMM1_A and DIMM1_B. See "
General Memory Module Installation Guidelines
"
in "Installing System Options."
Error: Incorrect memory configuration.
Memory slots DIMM3_A and DIMM3_B must be
empty if dual rank memory DIMMS are in
slots DIMM2_A and DIMM2_B.
Memory modules are
installed in bank 3. Dual
-
rank memory modules are
installed in banks 1 and 2.
Remove memory modules from slots DIMM3_A and DIMM3_B. See "
General
Memory Module Installation Guidelines
" in "Installing System Options."
Error 8602: Auxiliary device failure.
Verify that the keyboard and mouse are
securely attached to correct connectors.
Loose or improperly
connected mouse or
keyboard cable to the
custom cable; faulty mouse
or keyboard.
Replace the mouse. If the problem persists, replace the keyboard.
Gate A20 failure
Faulty keyboard controller
(faulty server module
board).
See "
Getting Help
."
General failure
Operating system corrupted
or improperly installed.
Reinstall the operating system.
Keyboard controller failure
Faulty keyboard controller
(faulty server module
board).
See "
Getting Help
"
Keyboard data line failure
Keyboard failure
Keyboard stuck key failure
Loose or improperly
connected keyboard cable;
faulty keyboard to the
custom cable; faulty
keyboard controller.
Ensure that the keyboard is properly connected. If the problem persists,
replace the keyboard. If the problem persists, see "
Getting Help
."
Keyboard fuse has failed.
Keyboard fuse has failed.
Replace the keyboard.
Manufacturing mode detected
System is incorrectly
configured.
After the message appears during system module boot, press
turn off manufacturing mode.
Memory address line failure at address,
read value expecting value
Memory double word logic failure at
address, read value expecting value
Memory odd/even logic failure at start
address to end address
Memory write/read failure at address, read
value expecting value
Faulty or improperly installed
memory modules, or faulty
server module board.
Ensure that all memory modules are properly installed. See "
Troubleshooting
Server Module Memory
" in "Troubleshooting Your System." If the problem
persists, see "
Getting Help
."
Memory tests terminated by keystroke
The spacebar was pressed
during POST to terminate
the memory test.
Information only.
No boot device available
Faulty or missing diskette
drive, optical drive, or hard
drive.
Check the Integrated Devices configuration settings in the System Setup
program. See "Using the System Setup Program" in your User's Guide. Ensure
that either SCSI Controller, Diskette Controller, or IDE CD-ROM Controller
is enabled. If the server module is booting from a SCSI controller, ensure that
the controller is properly connected. If the problem persists, replace the drive.
See "
Hard Drives
."
No boot sector on hard-disk drive
An operating system is not
on the hard drive.
Check the hard-drive configuration settings in the System Setup program. See
"Using the System Setup Program" in your User's Guide.