Dell PowerEdge R310 User Manual
Page 49
About Your System
49
Unsupported
memory
configuration.
DIMM mismatch
across slots
detected:
x,
x,...
Invalid memory
configuration.
Memory modules are
mismatched in the
specified slots.
Ensure that the memory
modules are installed in a
valid configuration.
See "General Memory
Module Installation
Guidelines" on page 106.
Warning: A fatal
error has caused
system reset!
Please check the
system event log!
A fatal system error occurred
and caused the system to
reboot.
Check the SEL for
information that was logged
during the error. See the
applicable troubleshooting
section in "Troubleshooting
Your System" on page 145 for
any faulty components
specified in the SEL.
Warning: Control
Panel is not
installed.
The control panel is not
installed or has a faulty cable
connection.
Install the control panel, or
check the cable connections
between the display module,
the control panel board,
and the system board.
See "Control Panel
Assembly" on page 132.
Warning! No micro
code update
loaded for
processor
n.
Micro code update failed.
Update the BIOS firmware.
See "Getting Help" on
page 169.
Table 1-3.
System Messages (continued)
Message
Causes
Corrective Actions
R310HOM.book Page 49 Thursday, March 4, 2010 1:03 AM