About Your System

27

E122A

CPU # VTT

Regulator

failure.

Reseat CPU.

Specified processor VTT
voltage regulator has
failed.

Reseat the processor. See
"Troubleshooting the
Processor" on page 160.

If the problem persists,
see "Getting Help" on
page 169.

E122C

CPU Power

Fault. Power

cycle AC.

A power fault was
detected when powering
up the processor.

Remove AC power to the
system for 10 seconds and
restart the system.

If the problem persists,
see "Getting Help" on
page 169.

E122D

Memory

Regulator #

Failed. Reseat

DIMMs.

One of the memory
regulators has failed.

Reseat the memory
modules. See
"Troubleshooting System
Memory" on page 153.

E122E

On-board

regulator

failed. Call

support.

One of the on-board
voltage regulators failed.

Remove AC power to the
system for 10 seconds and
restart the system.

If the problem persists,
see "Getting Help" on
page 169.

E1310

Fan ## RPM

exceeding

range. Check

fan.

RPM of specified fan is
outside of the intended
operating range.

See "Troubleshooting
System Cooling
Problems" on page 151.

E1311

Fan module ##

RPM exceeding

range. Check

fan.

RPM of specified fan in
specified module is
outside of intended
operating range.

See "Troubleshooting
System Cooling
Problems" on page 151.

E1313

Fan redundancy

lost. Check

fans.

The system is no longer
fan redundant. Another
fan failure would put the
system at risk of
over-heating.

Check LCD for
additional scrolling
messages. See
"Troubleshooting a Fan"
on page 152.

Table 1-2.

LCD Status Messages (Optional) (continued)

Code

Text

Causes

Corrective Actions