Dell PowerEdge R310 User Manual
Page 32
32
About Your System
E1810
Hard drive ##
fault. Review
& clear SEL.
The specified hard drive
has experienced a fault.
See "Troubleshooting a
Hard Drive" on page 158.
E1812
Hard drive ##
removed. Check
drive.
The specified hard
drive has been removed
from the system.
Information only.
E1920
iDRAC6 Upgrade
Failed.
optional iDRAC6
upgrade has failed.
See "Getting Help" on
page 169.
E1A14
SAS cable A
failure. Check
connection.
SAS cable A is missing
or bad.
Reseat the cable. If the
problem persists,
replace cable.
If the problem persists,
see "Getting Help" on
page 169.
E1A15
SAS cable B
failure. Check
connection.
SAS cable B is missing
or bad.
Reseat the cable. If the
problem persists,
replace cable.
If the problem persists,
see "Getting Help" on
page 169.
E1A1D
Control panel
USB cable not
detected.
Check cable.
USB cable to the control
panel is missing or bad.
Reseat the cable. If the
problem persists, replace
cable.
If the problem persists,
see "Getting Help" on
page 169.
E2010
Memory not
detected.
Inspect DIMMs.
No memory was detected
in the system.
Install memory or reseat
memory modules. See
"Troubleshooting System
Memory" on page 153.
E2011
Memory
configuration
failure.
Check DIMMs.
Memory detected, but is
not configurable.
Error detected during
memory configuration.
See "Troubleshooting
System Memory" on
page 153.
Table 1-2.
LCD Status Messages (Optional) (continued)
Code
Text
Causes
Corrective Actions
R310HOM.book Page 32 Thursday, March 4, 2010 1:03 AM