Dell PowerEdge R310 User Manual
Page 33
About Your System
33
E2012
Memory
configured but
unusable.
Check DIMMs.
Memory configured, but is
unusable.
See "Troubleshooting
System Memory" on
page 153.
E2013
BIOS unable to
shadow memory.
Check DIMMs.
The system BIOS failed to
copy its flash image into
memory.
See "Troubleshooting
System Memory" on
page 153.
E2014
CMOS RAM
failure. Power
cycle AC.
CMOS failure. CMOS
RAM not functioning
properly.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 169.
E2015
DMA Controller
failure. Power
cycle AC.
DMA controller failure.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 169.
E2016
Interrupt
Controller
failure. Power
cycle AC.
Interrupt controller
failure.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 169.
E2017
Timer refresh
failure. Power
cycle AC.
Timer refresh failure.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 169.
Table 1-2.
LCD Status Messages (Optional) (continued)
Code
Text
Causes
Corrective Actions
R310HOM.book Page 33 Thursday, March 4, 2010 1:03 AM