beautypg.com

Dell PowerEdge R310 User Manual

Page 33

background image

About Your System

33

E2012

Memory

configured but

unusable.

Check DIMMs.

Memory configured, but is
unusable.

See "Troubleshooting
System Memory" on
page 153.

E2013

BIOS unable to

shadow memory.

Check DIMMs.

The system BIOS failed to
copy its flash image into
memory.

See "Troubleshooting
System Memory" on
page 153.

E2014

CMOS RAM

failure. Power

cycle AC.

CMOS failure. CMOS
RAM not functioning
properly.

Remove AC power to the
system for 10 seconds and
restart the system.

If the problem persists,
see "Getting Help" on
page 169.

E2015

DMA Controller

failure. Power

cycle AC.

DMA controller failure.

Remove AC power to the
system for 10 seconds and
restart the system.

If the problem persists,
see "Getting Help" on
page 169.

E2016

Interrupt

Controller

failure. Power

cycle AC.

Interrupt controller
failure.

Remove AC power to the
system for 10 seconds and
restart the system.

If the problem persists,
see "Getting Help" on
page 169.

E2017

Timer refresh

failure. Power

cycle AC.

Timer refresh failure.

Remove AC power to the
system for 10 seconds and
restart the system.

If the problem persists,
see "Getting Help" on
page 169.

Table 1-2.

LCD Status Messages (Optional) (continued)

Code

Text

Causes

Corrective Actions

R310HOM.book Page 33 Thursday, March 4, 2010 1:03 AM