System messages – Dell PowerEdge R310 User Manual
Page 38
38
About Your System
•
Clear the SEL—You can perform this task remotely, but you will lose the
event history for the system.
•
Power cycle—Turn off the system and disconnect it from the electrical
outlet; wait approximately ten seconds, reconnect the power cable, and
restart the system.
Any of these actions will remove fault messages, and return the status
indicators and LCD colors to the normal state. Messages will reappear under
the following conditions:
•
The sensor returns to a normal state but fails again, resulting in a new
SEL entry.
•
The system is reset and new error events are detected.
•
A failure is recorded from another source that maps to the same
display entry.
System Messages
System messages appear on the screen to notify you of a possible problem
with the system.
NOTE:
If you receive a system message not listed in the table, check the
documentation for the application that is running when the message appears or the
operating system's documentation for an explanation of the message and
recommended action.
Table 1-3.
System Messages
Message
Causes
Corrective Actions
Alert! iDRAC6 not
responding.
Rebooting.
The optional iDRAC6 is not
responding to BIOS
communication either
because it is not functioning
properly or has not
completed initialization.
The system will reboot.
Wait for the system to
reboot.
R310HOM.book Page 38 Thursday, March 4, 2010 1:03 AM