beautypg.com

Dell PowerEdge M710HD User Manual

Page 122

background image

122

About Your System

Alert! Unsupported
memory, incomplete
sets, or unmatched
sets. The
following memory
DIMMs have been
disabled:l,m,n

The installed memory

configuration is invalid.

Add, move, or remove

memory modules to achieve

a configuration supported by

the system. See "System

Memory" on page 171.

Caution! NVRAM_CLR
jumper is
installed on
system board.

NVRAM_CLR jumper is

set to "on."

Set the NVRAM_CLR

jumper to "off." See "Blade

System Board Jumper

Settings" on page 331

for the

jumper location.

CPUs with
different cache
sizes detected.

Mismatched processors are

installed.

Install a correct version of

the processor so that both

processors have the same

cache size. See "Processors"

on page 243.

Decreasing
available memory.

Faulty or improperly

installed memory

modules.

Ensure that all memory

modules are properly

installed. See

"Troubleshooting Blade

Memory" on page 319.

DIMMs
disabled - SMI
channel training
failure.

The memory modules are

not properly seated.
The memory module

connectors or the

processor socket may be

exposed to dust.
The processor has bent

pins.

Reseat or replace Memory

Modules. See "System

Memory" on page 171.
Ensure that the memory

module connectors and

processor sockets are clean.
Verify that there are no bent

pins on the processor. If the

processor has bent pins, see

"Getting Help" on page 361.

DIMMs
disabled - Memory
Buffer
communication
error.

Table 1-27. Blade Messages

(continued)

Message

Causes

Corrective Actions