beautypg.com

Dell PowerEdge M710HD User Manual

Page 106

background image

106

About Your System

E1311 Fan module ##

RPM exceeding
range. Check
fan.

Speed of the specified fan

in specified module is

outside of intended

operating range.

See "Troubleshooting Fan

Modules" on page 315.

E1313 Fan

redundancy
lost. Check
fans.

The system is no longer fan

redundant. Another fan

failure would put the

system at risk of over-

heating.

Check LCD for additional

scrolling messages. See

"Troubleshooting Fan

Modules" on page 315.

E1410 Internal

Error
detected.
Check "FRU
X".

Specified processor has an

internal error. The error

may or may not have been

caused by the processor.

Remove AC power to the

system for 10 seconds and

restart the system.
If the problem persists,

see "Getting Help" on

page 361.

E1414 CPU # temp

exceeding
range. Check
CPU heatsink.

Specified processor is out of

acceptable temperature

range.

Ensure that the processor

heat sinks are properly

installed. See

"Troubleshooting

Processors" on page 322

and "Troubleshooting Fan

Modules" on page 315.

E1418 CPU # not

detected.
Check CPU is
seated
properly.

Specified processor is

missing or bad, and the

system is in an unsupported

configuration.

Ensure that the specified

processor is properly

installed. See

"Troubleshooting

Processors" on page 322.

E141C Unsupported

CPU
configuration
Check CPU or
BIOS
revision.

Processors are in an

unsupported configuration.

Ensure that your

processors match and

conform to the type

described in the processor

technical specifications

outlined in your system’s

Getting Started Guide.

Table 1-26. LCD Status Messages

(continued)

Code

Text

Cause

Corrective Actions