Dell PowerEdge M710HD User Manual
Page 106
106
About Your System
E1311 Fan module ##
RPM exceeding
range. Check
fan.
Speed of the specified fan
in specified module is
outside of intended
operating range.
E1313 Fan
redundancy
lost. Check
fans.
The system is no longer fan
redundant. Another fan
failure would put the
system at risk of over-
heating.
Check LCD for additional
scrolling messages. See
E1410 Internal
Error
detected.
Check "FRU
X".
Specified processor has an
internal error. The error
may or may not have been
caused by the processor.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
E1414 CPU # temp
exceeding
range. Check
CPU heatsink.
Specified processor is out of
acceptable temperature
range.
Ensure that the processor
heat sinks are properly
installed. See
E1418 CPU # not
detected.
Check CPU is
seated
properly.
Specified processor is
missing or bad, and the
system is in an unsupported
configuration.
Ensure that the specified
processor is properly
installed. See
E141C Unsupported
CPU
configuration
Check CPU or
BIOS
revision.
Processors are in an
unsupported configuration.
Ensure that your
processors match and
conform to the type
described in the processor
technical specifications
outlined in your system’s
Getting Started Guide.
Table 1-26. LCD Status Messages
(continued)
Code
Text
Cause
Corrective Actions