About Your System

E2012 Memory

configured
but unusable.
Check DIMMs.

Memory configured, but is

unusable.

See "Troubleshooting

Blade Memory" on

page 319.

E2013 BIOS unable

to shadow
memory. Check
DIMMs.

The system BIOS failed to

copy its flash image into

memory.

See "Troubleshooting

Blade Memory" on

page 319.

E2014 CMOS RAM

failure.
Power cycle
AC.

CMOS failure. CMOS

RAM not functioning

properly.

Remove AC power to the

system for 10 seconds and

restart the system.
If the problem persists,

see "Getting Help" on

page 361.

E2015 DMA

Controller
failure.
Power cycle
AC.

DMA controller failure.

Remove AC power to the

system for 10 seconds and

restart the system.
If the problem persists,

see "Getting Help" on

page 361.

E2016 Interrupt

Controller
failure.
Power cycle
AC.

Interrupt controller failure. Remove AC power to the

system for 10 seconds and

restart the system.
If the problem persists,

see "Getting Help" on

page 361.

E2017 Timer refresh

failure.
Power cycle
AC.

Timer refresh failure.

Remove AC power to the

system for 10 seconds and

restart the system.
If the problem persists,

see "Getting Help" on

page 361.

Table 1-26. LCD Status Messages

(continued)

Code

Text

Cause

Corrective Actions