Dell PowerEdge M710HD User Manual
Page 108
108
About Your System
E1618 Predictive
failure on
Power Supply
# (### W).
Check PSU.
Specified power supply has
detected a condition that
may predict a future power-
down event, such as an
over-temperature warning
or PSU communication
error, that could develop
into a fault condition in the
power supply.
E161C Power Supply
# (### W)
lost AC
power. Check
PSU cables.
Specified power supply is
attached to the system, but
it has lost its AC input.
Check the AC power
source for the specified
power supply. If the
problem persists, see
E1620 Power Supply
# (### W) AC
power error.
Check PSU
cables.
Specified power supply's
AC input is outside of the
allowable range.
Check the AC power
source for the specified
power supply. If the
problem persists, see
E1624 Lost power
supply
redundancy.
Check PSU
cables.
The power supply
subsystem is no longer
redundant. If the remaining
power supply fails, the
system shuts down.
E1626 Power Supply
Mismatch.
PSU1 = ### W,
PSU2 = ### W.
The power supplies in the
system are not the same
wattage.
Ensure that power
supplies with matching
wattage are installed. See
the Technical
Specifications outlined in
your system’s Getting
Started Guide.
Table 1-26. LCD Status Messages
(continued)
Code
Text
Cause