Using the System Setup Program
49
Remote Access Configuration
NOTE:
When Flow Control is set to Software, the Hyper Terminal on remote side is
discontinued by pressing . But the is also the Setup Key Stroke
for setting onboard NIC PXE Option ROM Configuration. Therefore, we suggest
users change to
that the Hyper Terminal on remote side is discontinued when pressing .
IPv6 AutoConfig
Enable or disable IPv6 auto config.
IPv6 Prefix Length
Enter the IPv6 prefix length in decimal in the form of xxx
(xxx less than 128 and in decimal only).
IPv6 IP Address
Enter IPv6 address in string form.
IPv6 Gateway Address
Enter IPv6 Gateway address in string from.
Option
Description
Remote Access (Enabled
default)
Selects remote access type.
Serial Port Number
(COM1 default)
Selects serial port for console redirection.
Current SOL Baud Rate
Displays the current SOL Baud Rate.
Serial Port Mode
(115200 8,n,1 default)
Selects serial port settings. The default value may change
if SOL baud rate is fixed by customer request.
Flow Control
(None default)
Selects flow control for console redirection.
Redirection After BIOS
POST (Enabled default)
Selects the settings for the redirection.
• Disabled: turns off the redirection after POST.
• Enabled: redirection is always active.
Terminal Type
(ANSI default)
Selects the target terminal type.
Option
Description