beautypg.com

Collecting system event log for investigation, Post error codes – Dell PowerEdge C2100 User Manual

Page 22

background image

18

About Your System

Table 1-9. Fault Indicator Codes

Collecting System Event Log for Investigation

If the front panel LED blinks for 30 to 60 seconds upon applying AC power to

the power supply, the baseboard management controller (iBMC) is

initializing. If not, then the iBMC is not functioning. If the iBMC is working,

try to gather system event log (SEL) information for investigation.

POST Error Codes

Yellow off

Power supply is off or AC input

voltage is out of normal operating range

(90–264 VAC).

Blinks green

Standby power is on.

Fault Indicator

Condition

Blinks amber

Host has critical or non-critical events

detected by iBMC, please check iBMC SEL

for details.

Amber off

SEL is cleared or fail symptom has been

recovered. This failed LED will be turned

off in power off state.

Code

Log in iBMC Error Message

Corrective Action

0000 Yes

Timer Error

Remove AC power to the system for

10 seconds and restart the system.
If the problem persists, see "Getting

Help" on page 133.

0003 Yes

CMOS Battery

Low

See "Troubleshooting the System Battery"

on page 114.

Power Indicator

Condition

book.book Page 18 Friday, November 8, 2013 11:29 AM