Capacitance, Thermal resistance, Ac test loads – Cypress CY14E102L User Manual
Page 8: Ac test conditions

ADVANCE
CY14E102L, CY14E102N
Document Number: 001-45755 Rev. *A
Page 8 of 21
AC Test Conditions
Input Pulse Levels ....................................................0V to 3V
Input Rise and Fall Times (10% - 90%) ........................ <5 ns
Input and Output Timing Reference Levels .................... 1.5V
Capacitance
The following table lists the capacitance parameters.
Parameter
Description
Test Conditions
Max
Unit
C
IN
Input Capacitance
T
A
= 25
°C, f = 1 MHz,
V
CC
= 0 to 3.0V
7
pF
C
OUT
Output Capacitance
7
pF
Thermal Resistance
The following table lists the thermal resistance parameters.
Parameter
Description
Test Conditions
48-FBGA 44-TSOP II 54-TSOP II
Unit
Θ
JA
Thermal Resistance
(Junction to Ambient)
Test conditions follow standard test methods and
procedures for measuring thermal impedance, in
accordance with EIA/JESD51.
28.82
31.11
30.73
°C/W
Θ
JC
Thermal Resistance
(Junction to Case)
7.84
5.56
6.08
°C/W
AC Test Loads
5.0V
OUTPUT
5 pF
R1
R2
512
Ω
5.0V
OUTPUT
30 pF
R1
R2
512
Ω
for tri-state specs
963
Ω
963
Ω
Note
11. These parameters are guaranteed but not tested.