beautypg.com

2 setting frame translation types, 2 setting frame translation types -30 – Cabletron Systems HSIM-F6 User Manual

Page 54

background image

Chapter 3: Local Management

3-30

HSIM-F6 User’s Guide

The Interpret 802.3 length for frames > 64 bytes field toggles between the
following options:

[DISABLED] (default setting)

[ENABLED]

If you retain the default setting of [DISABLED], the HSIM-F6 only
examines 802.3 frames that are the Ethernet minimum 64 bytes in length.
This allows for optimal switching performance, as the HSIM-F6 assumes
all frames over 64 bytes in length contain no padding.

If this field is set to [ENABLED] the HSIM-F6 examines ALL 802.3
frame length fields to determine whether any of the frames contain
padding. In this setting, the HSIM-F6 removes unnecessary padding from
any 802.3 frame, regardless of the size. Refer to

Section 3.10.4

for

information on when to set this field to [ENABLED].

Section 3.10.5

describes how to perform this task.

SAVE

This command saves all configuration changes to memory.

DEFAULT

This command sets all translation types to their default values.

3.10.2

Setting Frame Translation Types

To change the frame translations from the default settings, perform the
following steps:

1.

Use the arrow keys to highlight the desired frame type field, located
inside the brackets.

2.

Use the SPACE bar to toggle between the available choices.

3.

With the desired frame type selected, use the arrow keys to highlight
the SAVE command at the bottom of the screen, then press ENTER.
The “Saved OK” message appears indicating that the changes have
been saved to memory.