1 hsim-f6 configuration screen fields, Hsim-f6 configuration screen fields -22 – Cabletron Systems HSIM-F6 User Manual
Page 46
Chapter 3: Local Management
3-22
HSIM-F6 User’s Guide
3.8.1
HSIM-F6 Configuration Screen Fields
The following list describes each of the HSIM-F6 Configuration screen
fields:
SMT Version
This field displays the current version of Station Management (SMT) the
HSIM-F6 is using.
Treq
This field displays the Token Rotation Time (TRT) of the HSIM-F6.
Tneg
This field displays the negotiated token rotation time (in milliseconds)
that the stations on the ring established through the token claiming
process.
Tnotify
This field displays the interval (in seconds) at which the HSIM-F6
transmits Neighbor Information Frames (NIFs). The HSIM-F6 uses NIFs
to periodically announce its address and basic station description. To
change the HSIM-F6 Tnotify period from the default thirty seconds,
perform the following steps:
1.
Use the arrow keys to highlight the Tnotify field.
2.
Enter a value between 2 and 30.
3.
Use the arrow keys to highlight the SAVE command at the bottom of
the screen and press ENTER.
The HSIM-F6 now sends NIFs at the new interval.
SAVE
This command saves all configuration changes to memory.