Technical Specifications
24
DA-10051-00A-008 — 02.28.2000
Compaq AlphaServer GS140
System Unit
Dimensions (HxWxD)
67 x 31.5 x 34.4 in/170 x 80 x 87.5 cm
Shipping Dimensions
76.7 x 43.1 x 47.5 in / 195 x 109.5 x 121 cm
Weight Full Configuration
Without batteries
900 lbs/408 kg
With batteries
1,200 lbs/545 kg
Shipping Weight Full Configuration
Without batteries
1000 lbs/448 kg
With batteries
1300 lbs/585 kg
Clearances
Operating
Service
Front
40 in/1 m
59 in/1.5 cm
Rear
40 in/1 m
40 in/1 m
Sides
0
0
Environmental
Temperature
Operating
59
°
to 82
°
F/15
°
to 28
°
C
Non-operating
–40
°
to 151
°
F/–40
°
to 66
°
C
Humidity
Operating
20% to 80%
Non-operating
10% to 95%
Altitude
Operating
0 to 8,000 ft/0 to 2.4 km
Non-operating
30,000 ft/9,100 m
Vibration
Operating
2 to 22 Hz @ 0.01
″
da minimum
Non-operating
22 to 500 Hz @ 0.25 g maximum
Heat Dissipation (1)
Minimally configured system
−
system cabinet (1)
3,400 BTU/hr, 1,000W
Fully configured system
−
system cabinet (2)
15,700 BTU/hr, 4,600W
Fully configured system
−
system cabinet with 2 I/O
expansion cabinets (3)
30,600 BTU/hr, 9,000W
Regulatory
Agency Approvals
UL Listed to UL1950
UL Classified to IEC950
CSA Certified to CAN/CSA-C22.2, No. 950-M89
FCC Part 15 (Class A)
CE Declaration #1171
Reviewed to
AS 3260, Australian Standard
EN 60950, European Norm
Power Requirements (1)
3-Phase Power Subsystem (2)
US/Canada
Europe/AP
Japan
Nominal voltage
120/208V
380-415V
202V
Frequency range
50 to 60 Hz
50 to 60 Hz
50 to 60 Hz
Phases
3-phase star
3-phase star
3-phase delta
4-wire N-GND
4-wire N-GND
4-wire mid-GND or
3-wire junction
GND
Maximum input/current phase
24 A rms
12.8 rms
24 A rms
Surge current
50 A peak
50 A peak
50 A peak
Rating
30 A
16 A
30 A
Power cap (system)
DEC 12-12314-00 DEC 12-30333-02 DEC 12-12314-00
Receptacle (site)
DEC 12-12315-01 See footnote 4
DEC 12-12315-01
(Industry equivalent)
NEMA L21-30R
IEC 309
NEMA L21-30R
PCS/PDS/PDU/UPS cable
BC24W
BN29X
BC24W