Compaq AlphaServer GS140

Step 10

−−−−

MEMORY CHANNEL

−−−−

Optional (continued)

OpenVMS Systems (continued)
• In cases where nodes must be separated by a longer distance than standard copper cables allow, the CCMFB

option converts the output of the standard CCMAB controller or CCMLB line card to single-mode fibre optic

cable. The fibre optic connection may be up to 2,000 meters long between two CCMAB controllers connected

in virtual hub mode, or 3,000 meters between a CCMAB controller and a CCMHB hub. (The connection from

the CCMHB hub to a second system may also be 3,000 meters). The CCMFB option requires a second PCI

slot in the system from which it draws power only. It is normally connected to the corresponding CCMAB

controller with the short BN39B-01 cable. The CCMFB is also used in the CCMHB hub where it occupies a

slot normally used by the CCMLB line card, limiting expansion to four radial fibre optic connections.

• The CCMHB-BA hub expansion box provides additional slots for up to 8 fibre optic connections. Two standard

length, single-mode fibre optic cables are available (BN34R-10 and BN34R-31); however, users normally

provide this connection. Customers should reference the TIA/EIA 568-A Commercial Building

Telecommunications Cabling Standard, Section 12.3.4. Fibre optic connectivity is completely transparent to

the systems using it and has no performance impact.

MEMORY CHANNEL Controller/Network Hub
PCI System Area Network controller, maximum two

CCMAB-AA

System Area Network hub with 4 line cards; includes BN19P-2E power cord for Canada, Japan,

and US operations; country-specific power cord for other regions is required

CCMHB-AA

MEMORY CHANNEL hub expansion box with no line cards

CCMHB-BA

Expansion line card for CCMHB hub

CCMLB-AA

1-m cable for CCMAB and CCMHB

BN39B-01

4-m cable for CCMAB and CCMHB

BN39B-04

10-m cable for CCMAB and CCMHB

BN39B-10

Copper-to-single mode fibre optic converter

CCMFB-AA

TruCluster Production Server Software for Tru64 UNIX

QB-3RLAQ-AA

Tru64 UNIX Driver for MEMORY CHANNEL license

QB-4ZCAQ-AA

OpenVMS Cluster license for Alpha systems

QL-MUZAQ-AA

MEMORY CHANNEL Power Cords
Ireland, United Kingdom

BN19A-2E

Egypt, India

BN19S-2E

Central Europe

BN19C-2E

Israel

BN18L-2E

Switzerland

BN19E-2E

Italy

BN19M-2E

Denmark

BN19K-2E

Australia, New Zealand

BN19H-2E

MEMORY CHANNEL (Requirements for Currently Installed AlphaServer 8400 systems)
• Console firmware at revision V2.3 or higher
• CCMAA-BA adapter must be installed in slots 0-7 of a DWLPA-AA/AB/BA/BB PCI; no restriction for

DWLPB-AA/AB/BA/BB PCI bus

• For two system nodes, order one CCMAA-BA per system and one BC12N-10 cable to connect them.
• For three or more system nodes, order CCMHA-AA (MEMORY CHANNEL Hub) one CCMAA-BA and one

BC12N-10 cable per system node.

• CCMHA-AA (MEMORY CHANNEL Hub) is configured with four CCMLA-AA Line Cards and supports up to four

nodes. Expansion up to eight system nodes can be achieved by adding up to four additional CCMLA-AA Line

Cards, except TruCluster Production Server configurations

PCI to MEMORY CHANNEL controller, maximum two

CCMAA-BA

MEMORY CHANNEL Hub with four line cards

CCMHA-AA

MEMORY CHANNEL Line Card for use with MEMORY CHANNEL Hub (CCMHA-AA)

CCMLA-AA