3 device settings – Baumer GK473 User Manual
Page 7
Manual_GK473_DeviceNet_EN.doc
7/31
Baumer IVO GmbH & Co. KG
04.05.11
Villingen-Schwenningen,
Germany
4.3 Device
settings
4.3.1 How to open the housing
Snap-lock
Setting the DeviceNet user ID (Mac ID) and Baudrate requires partial opening of the gateway housing.
Please use a small screw-driver, press-in the snap-locks provided on top and bottom behind the screw
terminals and pull out the housing halfway until stop so that the operating elements are accessible. The
housing is closed again by pulling it back to its original position until both locks snap in again.
4.3.2 Setting the DeviceNet user ID (Mac ID)
The DeviceNet user ID (Mac ID) is set decimally within the range from 00 to 63 using two BCD rotary
switches. (Any settings higher than 63 are automatically assigned 63)
Default: Mac ID 63
Example: 01
4.3.3 Setting
the
Baudrate
Binary setting of the Baudrate is by utilizing the 3-pole DIP switches 1 to 3.
Default : Baudrate 125kBit/s
Baudrate
DIP switch position
1
2
3
125 kBit/s
OFF OFF OFF
250 kBit/s
OFF
OFF
ON
500 kBit/s
OFF
ON
OFF
Example: 500KBit/s