Example, Spas connected, spa identifier – Baumer GK473 User Manual
Page 21

Manual_GK473_DeviceNet_EN.doc
21/31
Baumer IVO GmbH & Co. KG
04.05.11
Villingen-Schwenningen,
Germany
7.4 Attribute 4: Batched information on connected SPAs
Class
Instance Attribute Access Rule
Name
DeviceNet
Data type
Default
Value
100 1
4
Get
connected
SPA
ARRAY[16]
of USINT
Output are 16 Bytes indicating all SPAs connected and their respective identifiers on the RS485 sub-bus.
They provide the following binary codes:
Example:
Result: SPAs with identifiers 0, 1, 2, 4, 5, 6, 7 and 30 are connected
Byte[0]..[15]
binär
0 31 62 93 2
0
1 32 63 94 2
1
2 33 64 95 2
2
3 34 65 96 2
3
4 35 66 97 2
4
5 36 67 98 2
5
6 37 68 bc 2
6
7 38 69 res. 2
7
8 39 70 res. 2
0
9 40 71 res. 2
1
10 41 72 res. 2
2
11 42 73 res. 2
3
12 43 74 res. 2
4
13 44 75 res. 2
5
14 45 76 res. 2
6
15 46 77 res. 2
7
16 47 78 res. 2
0
17 48 79 res. 2
1
18 49 80 res. 2
2
19 50 81 res. 2
3
20 51 82 res. 2
4
21 52 83 res. 2
5
22 53 84 res. 2
6
23 54 85 res. 2
7
24 55 86 res. 2
0
25 56 87 res. 2
1
26 57 88 res. 2
2
27 58 89 res. 2
3
28 59 90 res. 2
4
29 60 91 res. 2
5
30 61 92 res. 2
6
SPAs connected, SPA identifier
31 62 93 res. 2
7