Baumer GK473 User Manual
Page 28

Manual_GK473_DeviceNet_EN.doc
28/31
Baumer IVO GmbH & Co. KG
04.05.11
Villingen-Schwenningen,
Germany
8.4 Technical
data
Electrical ratings
Supply voltage
12...24 VDC
Current consumption
<200 mA
Display
4 LED´s as operating status indicators
LED operating states
DP (green) fieldbus operating status
DP (red) operating and error status
RX / TX (yellow) receiving / transmitting a token (RS485)
Interfaces
CANopen, DeviceNet, Profibus-DPV0
Interface to SPA
EIA RS485 (ASCII -Protocol)
Data memory
>10 years (flash / EEPROM)
Programmable parameters
Auto-Check functions
Auto Scan SPA
Auto Message SPA Position
Auto Message SPA Error
Emitted interference
DIN EN 61000-6-4
Interference immunity
DIN EN 61000-6-2
Mechanical design
Operating temperature
-10...+50 °C
Storing temperature
-20...+70 °C
Relative humidity
80 % non-condensing
Protection DIN EN 60529
IP 20
E-connection
D-SUB-female connector, 9-pins
Plug-in
screw
terminals
Housing type
DIN rail housing EN 50022
Dimensions W x H x L
22.6 x 99 x 114.5 mm
Mounting
DIN rail housing EN 50022
Weight approx.
120 g
Material
Polyamide green, UL 94V-0