7 GK473 Object, Class 0x64
Class Attributes
Attribute ID
Access Rule
Name
DeviceNet
Data type
Value
1 Get Revision
UINT 0x0001
2 Get Max
instance
UINT 0x0001
Class Services
Service Code
Get Attribute Single
0x0E
Instance Attributes
Attribute
ID
Access Rule
Name
DeviceNet
Data type
Value
Description
1
Get/Set
Autoscan SPA
BOOL
1
Autoscan of RS485 sub bus ON (0)-/OFF (1)
2
RWTransfer
Service
Code 0x32
Transfer SPA
command
transparent
ARRAY[16] of
USINT
0x20
For transparent transfer of all SPA commands
to the DeviceNet master“ through“ GK473 and
vice-versa
3 Get
RS485 Sub bus,
SPA state
information
complete
ARRAY[48] of
USINT
Information in binary code on state, number and
IDs of the SPAs (spindle position displays)
connected to RS485 sub bus
Byte 0..15 “SPA not in position”
Byte 16..31 “SPA in error states”
Byte 32..47 “SPA in timeout state”
4
Get
SPA connected
ARRAY[16] of
USINT
Information in binary code on number and IDs
of SPAs connected to RS485 sub bus
5
Get
SPA not in position
ARRAY[16] of
USINT
Information in binary code on number and IDs
of SPAs connected to RS485 sub bus being in
state not in position
6
Get
SPA in error state
ARRAY[16] of
USINT
Information in binary code on number and IDs
of SPAs connected to RS485 sub bus being in
error state
7 Get
SPA in timeout
state
ARRAY[16] of
USINT
Information in binary code on number and IDs
of SPAs connected to RS485 sub bus being in
timeout state
Instance Services
Service Code
Get Attribute Single
0x0E
Set Attribute Single
0x10
RWTransfer
0x32 Vendor Specific