Ac electrical characteristics, Electrical characteristics – Cypress CY7C1420AV18 User Manual
Page 21
CY7C1416AV18, CY7C1427AV18
CY7C1418AV18, CY7C1420AV18
Document Number: 38-05616 Rev. *F
Page 21 of 31
I
DD
V
DD
Operating Supply
V
DD
= Max,
I
OUT
= 0 mA,
f = f
MAX
= 1/t
CYC
200MHz
(x8)
600
mA
(x9)
600
(x18)
620
(x36)
675
167MHz
(x8)
500
mA
(x9)
500
(x18)
525
(x36)
570
I
SB1
Automatic Power down
Current
Max V
DD
,
Both Ports Deselected,
V
IN
≥ V
IH
or V
IN
≤ V
IL
f = f
MAX
= 1/t
CYC
,
Inputs
Static
300MHz
(x8)
345
mA
(x9)
345
(x18)
360
(x36)
400
278MHz
(x8)
325
mA
(x9)
330
(x18)
345
(x36)
370
250MHz
(x8)
320
mA
(x9)
320
(x18)
330
(x36)
350
200MHz
(x8)
300
mA
(x9)
300
(x18)
300
(x36)
315
167MHz
(x8)
285
mA
(x9)
285
(x18)
290
(x36)
300
AC Electrical Characteristics
Over the Operating Range
Parameter
Description
Test Conditions
Min
Typ
Max
Unit
V
IH
Input HIGH Voltage
V
REF
+ 0.2
–
–
V
V
IL
Input LOW Voltage
–
–
V
REF
– 0.2
V
Electrical Characteristics
(continued)
DC Electrical Characteristics
Over the Operating Range
[12]
Parameter
Description
Test Conditions
Min
Typ
Max
Unit