Start Times/Days and Start Conditions
Expand the Start Program section, and then perform any of the following tasks:
• To set up start times, click the Enabled check box in the upper-right corner of the Timed Start section. Click
the Add Start Time button, and then type the start time for the program in the box. Click the arrow in the
Water Schedule box, and then select the schedule type that you want. Update the additional Water
Schedule inputs as needed.
• To set up a moisture sensor start condition, click the Enabled check box at the right end of the Moisture
Start heading. In the field on the left, click the arrow, and then select the moisture sensor that you want to
use for this start condition. In the Limit Type field, click the arrow, and then select whether you want to
use the upper or lower limit. In the Limit field, type the limit that you want to use for the start condition.
• To set up an event switch start condition, click the Enabled check box at the right end of the Event Switch
Start heading. In the field on the left, click the arrow, and then select the event switch device that you
want to use for this start condition. In the Limit Type field, click the arrow, and then select whether you
want the program to start when the switch is open or closed.
• To set up a temperature sensor start condition, click the Enabled check box at the right end of the
Temperature Start heading. In the field on the left, click the arrow, and then select the temperature
sensor that you want to use for this start condition. In the Limit Type field, click the arrow, and then select
whether you want to use the upper or lower limit. In the Limit field, type the temperature that you want
to use for the start condition.
Water Windows
Expand the Water Window section, and then perform the following task:
• Click the arrow in the top center box, and then select whether you want to set up a Daily or Weekly water
window schedule. The boxes in the grid represent the hours in a day starting with 12:00 midnight on the
left. Blue boxes mean that watering is allowed. Use the Turn All Off or Turn All On buttons to change the
water window settings with one click.
Stop Conditions
Expand the Stop Program section, and then perform any of the following tasks:
• To set up a moisture sensor stop condition, click the Enabled check box at the right end of the Moisture
Stop heading. In the field on the left, click the arrow, and then select the moisture sensor that you want to
use for this stop condition. In the Limit Type field, click the arrow, and then select whether you want to
use the upper or lower limit. In the Limit field, type the limit that you want to use for the stop condition.
• To set up an event switch stop condition, click the Enabled check box at the right end of the Event Switch
Stop heading. In the field on the left, click the arrow, and then select the event switch device that you
want to use for this stop condition. In the Limit Type field, click the arrow, and then select whether you
want the program to stop when the switch is open or closed.
• To set up a temperature sensor stop condition, click the Enabled check box at the right end of the
Temperature Stop heading. In the field on the left, click the arrow, and then select the temperature sensor
that you want to use for this stop condition. In the Limit Type field, click the arrow, and then select
whether you want to use the upper or lower limit. In the Limit field, type the temperature that you want
to use for the stop condition.
Pause Conditions
Expand the Pause Program section, and then perform any of the following tasks:
• To set up a moisture sensor pause condition, click the Enabled check box at the right end of the Moisture
Pause heading. In the field on the left, click the arrow, and then select the moisture sensor that you want