Zone water times – Baseline Systems BaseStation 3200 User Manual
Page 61

C h a p t e r 5 – R e f e r e n c e
Page 59
Baseline 3200
Calibrate Failure: saturation not reached
Water flow rate has exceeded limit
Learn Flow Zone Successful
Watering Stopped by Low Temperature
The valve is an open-circuit
The valve current is too high
Pause biCoder has paused watering
Pause Switch has paused watering
Insufficient time between program starts
Rain/Off Delay has stopped watering
Rain Switch has stopped watering
The valve is a short-circuit
The Start Time was Skipped
Two-wire Current is too High
Unscheduled Flow exceeded limit
Water Window has stopped watering
Zone flow exceeds design flow
High Flow has terminated zone watering
Low Flow has terminated zone watering
Zone Water Times
This dial position is used to configure zones after
they have been assigned to a valve decoder. Refer
to the sample screen to the right for the following
field functions.
Press ENTR to quickly move to the next zone.
Zone – when highlighted use the + and – keys to change the zone number to be
programmed.
Enabled – use this to enable a zone for normal operation. A single zone can be
disabled to keep it from running during maintenance or other conditions.
Zone Mode – there are three modes for zones in the BaseStation 3200
Timed
This is the default for newly assigned zones and in this mode it
can be programmed and will water in an independent manner
(like other clocks).