Assigning other devices – Baseline Systems BaseStation 3200 User Manual
Page 34

C h a p t e r 1 – G e t t i n g S t a r t e d
Page 32
Baseline 3200
Zone Status
Note that the status of each zone is shown in
the Zone Number list. The zone status codes
are:
OK – Working properly
OP – Open circuit
SC – Short circuit
ER – Communication error
Zone Numbers are Pre-Assigned in R-series
All conventional wire versions (R-series) of the 3200 have been pre-assigned at the factory such
that terminal 1 is assigned to zone 1, terminal 2 is assigned to zone 2, etc. However, you can
change these zone numbers to organize Scheduling Groups, Primary and Linked zones to achieve
optimal watering behavior.
To change or re-order zone numbers in an R-series unit, use the CLEAR function as outlined
above, and then Assign each biCoder serial number to the desired Zone Number.
The serial numbers for all terminals in 3200R controllers are shown on the label next to the
terminals. The serial numbers for terminals in 5200R biCoders are shown on the door label.
Assigning Other Devices
Air Temperature Sensors
An Air Temperature Sensor does not need to be assigned
to any address, but it must be found by the controller.
To search for an air temperature sensor, turn the dial to
the AUX position, choose Temp/Pause using the
NEXT/PREV keys, and press ENTR. In the Pause Screen,
select Search.
If the air temperate sensor is found, it will show here.
Pause Devices
Pause Devices are assigned in the AUX dial position. For detailed instructions for Pause devices,
refer to Pause biCoders in Section 3 below.
Flow Meters and Flow Sensors
Flow Meters and Flow Sensors are configured on the Flow Menu dial position. Refer to Flow in
Section 3 below for detailed instructions for assigning and configuring Flow Meters and/or Flow
Sensors.