Appendix c - option setup, Hydraulic pump setup, Pump fittings and needle valve – Great Plains NP3000A Operator Manual User Manual
Page 166: Appendix c - option setup hydraulic pump setup

407-613M
2014-04-22
162
NP3000 and NP3000A
Great Plains Manufacturing, Inc.
Appendix C - Option Setup
Hydraulic Pump Setup
Pump Fittings and Needle Valve
Equipment Performance Risk:
Prior to first use, the pump fittings must be configured for the
type of hydraulic system provided by the tractor. If the system
is Open Center, the needle valve must also be adjusted.
As delivered, the hydraulic pump includes all fitting
necessary for use with any hydraulic system, but the
as-shipped pump configuration is suitable for use with no
system. Configure the pump before first use.
1.
Have the Ace Pump Instruction manual (HYD-MAN)
at hand for fitting use and adjustment details.
Refer to Figure 84 and table at right
2.
Determine the tractor hydraulic system type. Consult
the tractor operator manual.
3.
Remove one or both fittings ( or
necessary, adjust the needle valve
, based on the
system type.
Follow the instructions in the Ace manual.
For needle valve adjustment, obtain “dead head”
pressure by using the controller console to command the
flow control valve to closed (rate zero).
Figure 84
Pump Configuration
31965
Tractor Hydraulic
System Type
Pump Configuration
Required
Closed Center,
Load Sensing
(LS Closed)
Restrictor Orifice
OUT
Flow Limiter
IN
Needle Valve
closed
Closed Center,
Pressure Compensating
(PC Closed)
Restrictor Orifice
IN
Flow Limiter
OUT
Needle Valve
closed
Open Center
Restrictor Orifice
OUT
Flow Limiter
OUT
Needle Valve
adjusted
1
3
2
1
2