Anhydrous metering, Console, Speed sensor cable – Great Plains NP3000A Operator Manual User Manual
Page 142

138
NP3000 and NP3000A
Great Plains Manufacturing, Inc.
407-613M
2014-04-22
Anhydrous Metering
Based on the Raven AccuFlow™ system, Great Plains
factory-installed systems include all the components
identified on pages 147 through page 150, plus all the
piping, tubing, fittings and console harness
a
to hitch.
Select the dual-cooler system for application rates above
30 gpm, or for application in colder conditions, where the
nurse tank vapor pressure might not support a full
30 gpm rate with a single cooler.
Console
The Raven SCS 450 is used only with a hydraulic pump.
It controls and adjusts application rate based on flow
meter input, ground speed, and operator rate settings.
This console is sold separately from the cooler system
(above) or hydraulic pump system (page 137), which
includes the implement harnesses, flow meter and
valves.
This kit includes only the console and cab mounting
hardware.
This console package does not include a speed sensor
or speed sensor cable. The SCS 450 may be compatible
with a speed sensor, radar or GPS speed output already
installed on the tractor.
Speed Sensor Cable
If your existing or purchased speed sensor is compatible
with the Raven 115-0159-539 cable (intended for use
with a Raven radar), you may order it from Raven, or
from Great Plains:
Meter Package
Original Option
Single-Cooler Single-Section
(20)
Dual-Cooler Single-Section
(21)
Single-Cooler Section Control
(22)
Dual-Cooler Section Control
(23)
a. Console itself is sold separately.
Console Package
Part Number
RAVEN 450 CONSOLE
823-211C
N
H
3
34960
31639
Cable Package
Part Number
Radar Power Cable
115-0159-539
31650