beautypg.com

Carrier DOWNFLOW HORIZONTAL 2-SPEED User Manual

Page 20

background image

Table 10—Model 58TMA Orifice Size and Manifold Pressure for Correct Input—Continued

(TABULATED DATA BASED ON 21,000 BTUH HIGH HEAT/13,500 BTUH LOW HEAT PER BURNER,

DERATED 4% FOR EACH 1000 FT ABOVE SEA LEVEL)*

ALTITUDE

RANGE

(FT)

AVG GAS

HEAT VALUE

AT ALTITUDE

(BTU/CU FT)

SPECIFIC GRAVITY OF NATURAL GAS

0.58

0.60

0.62

0.64

0.66

Orifice

No.

Manifold

Pressure

High/Low

Orifice

No.

Manifold

Pressure

High/Low

Orifice

No.

Manifold

Pressure

High/Low

Orifice

No.

Manifold

Pressure

High/Low

Orifice

No.

Manifold

Pressure

High/Low

U.S.A.

Only

625

44

3.3/1.4

44

3.4/1.4

44

3.5/1.5

44

3.6/1.5

44

3.7/1.5

650

45

3.7/1.5

45

3.8/1.6

44

3.3/1.3

44

3.4/1.4

44

3.5/1.4

675

46

3.6/1.5

46

3.7/1.5

46

3.8/1.6

45

3.8/1.6

44

3.2/1.3

7001

700

47

3.8/1.6

46

3.4/1.4

46

3.6/1.5

46

3.7/1.5

46

3.8/1.6

725

47

3.5/1.5

47

3.6/1.5

47

3.8/1.6

46

3.4/1.4

46

3.5/1.5

to

750

48

3.7/1.5

47

3.4/1.4

47

3.5/1.5

47

3.6/1.5

47

3.7/1.5

775

48

3.5/1.5

48

3.6/1.5

48

3.8/1.6

47

3.4/1.4

47

3.5/1.4

8000

800

48

3.3/1.4

48

3.4/1.4

48

3.5/1.5

48

3.6/1.5

48

3.7/1.5

825

49

3.6/1.5

49

3.8/1.6

48

3.3/1.4

48

3.4/1.4

48

3.5/1.5

850

49

3.4/1.4

49

3.5/1.5

49

3.7/1.5

49

3.8/1.6

48

3.3/1.4

ALTITUDE

RANGE

(FT)

AVG GAS

HEAT VALUE

AT ALTITUDE

(BTU/CU FT)

SPECIFIC GRAVITY OF NATURAL GAS

0.58

0.60

0.62

0.64

0.66

Orifice

No.

Manifold

Pressure

High/Low

Orifice

No.

Manifold

Pressure

High/Low

Orifice

No.

Manifold

Pressure

High/Low

Orifice

No.

Manifold

Pressure

High/Low

Orifice

No.

Manifold

Pressure

High/Low

U.S.A.

Only

600

45

3.7/1.5

44

3.2/1.3

44

3.3/1.4

44

3.4/1.4

44

3.5/1.4

625

46

3.6/1.5

46

3.7/1.5

46

3.8/1.6

45

3.8/1.6

44

3.2/1.3

8001

650

47

3.8/1.6

46

3.4/1.4

46

3.5/1.5

46

3.7/1.5

46

3.8/1.6

675

47

3.5/1.4

47

3.6/1.5

47

3.7/1.5

47

3.8/1.6

46

3.5/1.4

to

700

48

3.7/1.5

48

3.8/1.6

47

3.5/1.4

47

3.6/1.5

47

3.7/1.5

725

48

3.4/1.4

48

3.6/1.5

48

3.7/1.5

48

3.8/1.6

47

3.4/1.4

9000

750

49

3.8/1.6

48

3.3/1.4

48

3.4/1.4

48

3.5/1.5

48

3.7/1.5

775

49

3.5/1.5

49

3.7/1.5

49

3.8/1.6

48

3.3/1.4

48

3.4/1.4

800

49

3.3/1.4

49

3.4/1.4

49

3.5/1.5

49

3.7/1.5

49

3.8/1.6

ALTITUDE

RANGE

(FT)

AVG GAS

HEAT VALUE

AT ALTITUDE

(BTU/CU FT)

SPECIFIC GRAVITY OF NATURAL GAS

0.58

0.60

0.62

0.64

0.66

Orifice

No.

Manifold

Pressure

High/Low

Orifice

No.

Manifold

Pressure

High/Low

Orifice

No.

Manifold

Pressure

High/Low

Orifice

No.

Manifold

Pressure

High/Low

Orifice

No.

Manifold

Pressure

High/Low

U.S.A.

Only

575

46

3.6/1.5

46

3.7/1.5

46

3.8/1.6

45

3.8/1.6

44

3.2/1.3

600

47

3.7/1.5

46

3.4/1.4

46

3.5/1.5

46

3.6/1.5

46

3.8/1.6

9001

625

47

3.4/1.4

47

3.6/1.5

47

3.7/1.5

47

3.8/1.6

46

3.5/1.4

650

48

3.6/1.5

48

3.8/1.6

47

3.4/1.4

47

3.5/1.5

47

3.6/1.5

to

675

48

3.4/1.4

48

3.5/1.4

48

3.6/1.5

48

3.7/1.5

48

3.8/1.6

700

49

3.7/1.5

49

3.8/1.6

48

3.3/1.4

48

3.5/1.4

48

3.6/1.5

10,000

725

49

3.4/1.4

49

3.5/1.5

49

3.7/1.5

49

3.8/1.6

48

3.3/1.4

750

50

3.8/1.6

49

3.3/1.4

49

3.4/1.4

49

3.5/1.5

49

3.6/1.5

775

50

3.5/1.5

50

3.7/1.5

50

3.8/1.6

49

3.3/1.4

49

3.4/1.4

* For 125-20 size only, input is 20,500 Btuh for high fire. Deduct 0.1-in. from manifold pressure shown in table. Change orifice size if manifold pressure falls below 3.2-in.

wc.

20