beautypg.com

Removing a seed disk, Row unit shut-off – Great Plains YP925TD Operator Manual User Manual

Page 64

background image

60

YP625TD and YP925TD

Table of Contents

Index

Great Plains Manufacturing, Inc.

401-755M

Table of Contents

Index

02/23/2011

Removing a Seed Disk

Refer to Figure 65
1.

Remove rain cover. If seed is present, close
shutter

to prevent more seed from entering meter.

Attach funnel (page 78) or place a tarp under the row
to collect seed.

2.

Hold seed disk in meter. Rotate disk clamp
counterclockwise 45

° to release disk.

3.

Tilting top of disk toward meter, slowly remove disk,
allowing seed to collect in funnel or to control flow to
tarp. Open shutter to release remaining seed up to
wing tube.

4.

Clean seed from all brushes. Clean disk seat (

in

Figure 62

page 59), so that new disks can seat fully.

Inspect brushes for excess wear and damage. See
Meter Brush Maintenance” on page 80.

5.

Inspect removed disks for excess wear and damage.
Set aside any disks requiring replacement. Clean
other removed disks and place in storage. See
Seed Disk Maintenance” on page 82.

6.

Re-install the rain cover (page 57).

Row Unit Shut-Off

Skip-row operations, such as switching from 110 cm
twin- or triple-row to 110 cm single-row, requires shutting
down unused rows.

Shutting off seeding at a row involves 4 to 6 steps:

1.

Identify the rows to shut off (page 61).

2.

Fully close seed inlet shutter (page 61).

3.

Replace seed disk with blank disk (page 61).

4.

Lock up row unit to reduce wear (optional, page 61).

5.

Reset marker extension (Option, page 120).

6.

Reset monitor active row pattern and row spacing to
avoid nuisance alarms (see Monitor manual).

Note: Meter drive is not disabled on 25AP row units

during shut-off.

Figure 65

Remove Disk

29611

3

1

4

4

1

2

Figure 66

Seed Inlet Shutter Closed

29609

2

1

This manual is related to the following products: