beautypg.com

05 power source compatibility details, 06 prewelding procedure, Ultrafeed va 4000s – Tweco VA 4000S Ultra-Feed User Manual

Page 32

background image

ULTRAFEED VA 4000S

OPERATION

4-6

Manual No. 0-5135

4.05 Power Source Compatibility Details

Machine

Details

PowerMaster 500

Fully Compatible

PowerMaster 500P

For GMAW - Set Motor Control S1 Switches for:
Runin Speed 25%, Motor Ramp Rate 0.3 S, Arc Established ON.
For Pulse GMAW - Set Motor Control S1 Switches for:
Runin Speed - 75%, Motor Ramp Rate - 0.2 S, Arc Established - ON

ExcelArc 6045

Fully Compatible

ExcelArc 8065

For GMAW - Set Motor Control S1 Switches for:
Runin Speed 50%, Motor Ramp Rate 0.2 S, Arc Established ON.

Fabstar 4030

Fully Compatible except: Actual arc amps on the wire feeder will not be show
and preset volts on the power source will not be displayed.

ArcMaster 300 MST

Fully Compatible

ArcMaster 400 MST

Fully Compatible

ArcMaster 400 MSTP Fully Compatible

Power Source Compatibility Details

4.06 Prewelding Procedure

Follow all installation instructions for the wire feeder, the welding power source, and the welding gun before attempting
to operate the Ultrafeed VA 4000 S.

1. Make sure all necessary connections have been made (Refer to “Connections” in the Installation chapter of

this manual).

2. Turn ON the power source, contoller and the wire feeder.